Enerco HeatStar HS170FAVT Operation Instructions And Owner'S Manual Download Page 8

Heatstar by Enerco, 4560 W. 160TH ST., CLEVELAND, OHIO 44135 • 866-447-2194
Mr. Heater is a registered trademarks of Mr. Heater Group, Inc.
© 2017, Mr. Heater Group, Inc. All rights reserved

Heatstar by Enerco reserves the right to make changes at any time, without notice or 
obligation, in colors, specifications, accessories, materials and models.

WARNING:

USE  ONLY  MANUFACTURER’S  REPLACEMENT  PARTS.  USE  OF  ANY  OTHER  PARTS 
COULD CAUSE INJURY OR DEATH. REPLACEMENT PARTS ARE ONLY AVAILABLE DIRECT 
FROM  THE  FACTORY  AND  MUST  BE  INSTALLED  BY  A  QUALIFIED  SERVICE  AGENCY. 

PARTS ORDERING INFORMATION:

PURCHASING: 

Accessories may be purchased at any Mr. Heater local dealer or direct from the 

factory 

FOR INFORMATION REGARDING SERVICE

Please call Toll-Free 866-447-2194
www.heatstarbyenerco.com
Please include the model number, date of purchase, and description of problem in all communication.
Our office hours are 8:00 AM – 5:00 PM, EST, Monday through Friday.

LIMITED WARRANTY

Heatstar by Enerco warrants its heaters and accessories to be free from defects in material and 
workmanship for a period of 1 year from date of purchase. Mr. Heater, Inc. will repair or replace 
this product free of charge if it has been proven to be defective within the 1-year period, and is 
returned at customer expense with proof of purchase to Mr. Heater, Inc. within the warranty period.

If   a  part   is   damaged   or   missing, call   our   Technical   Support   Department   at   866-447-2194
Address   any   Warranty   Claims   to   the   Service   Department,   HeatStar,   Inc., 4560   W.   160th   St., 
 Cleveland, Ohio   44135.   Include   your   name,   address   and   telephone   number   and   include   details 
 concerning  the  claim.  Also,  supply  us  with  the  purchase  date  and  the  name  and  address  of  the  
dealer  from  whom  you  purchased  our  product.  The  fore going  is  the  full  extent  of  the  responsibility 
 of  the  Company.  There  are  no  other  warranties, express  or  implied.  Specifically  there  is  no  warranty  
of  fitness  for  a  particular  purpose  and  there  is  no  warranty  of  merchantability.  In  no  event  shall 
 the  Company  be  liable  for  delay  caused  by  imperfections,  for  consequential  damages, or  for  any  
charges   of   the   expense   of   any   nature  incurred  without  its  written   consent.   The   cost  of  repair 
or  replacement   shall   be  the  exclusive  remedy   for  any  breach  of  warranty.   There  is   no   warranty 
against  infringement  of  the  like  and   no  implied  warranty  arising  from  course  of  dealing   or 
usage of trade. This warranty will not apply to any product which has been repaired or altered  
outside   of   the   factory   in   any   respect  which   in   our   judgment   affects   its   condition   or   operation. 

Some  states  do  not  allow  the  exclusion  or  limitation  of  incidental  or  consequential  damages,  so 
the  above  limitation  or  exclusion  may  not  apply  to  you.  This  Warranty  gives  you  specific  legal  
rights,  and  you  may  have  other  rights  which  vary  from  state  to  state.

ANSI Z83.7b/CGA 2.14b-2015

HS170FAVT

OPERATING INSTRUCTIONS 
AND OWNER’S MANUAL

READ INSTRUCTIONS CAREFULLY:

 Read and follow all instructions. Place instructions in a safe 

place for future reference. Do not allow anyone who has not read these instructions to assemble, 
light, adjust or operate the heater.

Model #

PRODUCT REGISTRATION:  Thank you for your purchase.  
Please log in to http://www.egiregistration.com to register your product.

Summary of Contents for HeatStar HS170FAVT

Page 1: ...t be performed by a qualified service agency This is an unvented gas fired portable heater It uses air oxygen from the area in which it is used Adequate combustion and ventilation air must be provided...

Page 2: ...E THE HEATER IN SPACES WHICH DO OR MAY CONTAIN VOLATILE OR AIRBORNE COMBUSTIBLES OR PRODUCTS SUCH AS GASOLINE SOLVENTS PAINT THINNER DUST PARTICLES OR UNKNOWN CHEMICALS WARNING CARBON MONOXIDE CAN KIL...

Page 3: ...odified from its original condition 3 Use only propane gas 4 Use only VAPOR WITHDRAWAL propane supply If there is any question about vapor withdrawal ask your propane dealer 5 Mount the propane cylind...

Page 4: ...o not use this heater for heating human living quarters Do not use in unventilated areas The flow of combustion and ventilation air must not be obstructed Proper ventilation air must be provided to su...

Page 5: ...ed replace it with part number F273786 3 Turn off the gas at the LP gas supply cylinder s when the heater is not in use 4 When the heater is to be stored indoors the connection between the LP gas supp...

Page 6: ...Length in Feet Amps 25 50 100 150 5 6 18 16 14 12 6 8 18 16 12 10 8 12 18 14 12 10 10 12 16 14 10 8 12 14 16 12 10 8 WARNING When using a thermostat controlled heater its exit area should be protecte...

Page 7: ...e Assembly 1 26152 20 Hose Assembly 20 HS only 1 14 26257 Regulator 28 WC 1 15 26433 POL Excess Flow Valve 1 16 26122 Male Fitting Conn 1 3 8MPT x 3 8SAE FLR 17 26101 Solenoid Valve Goyen 1 18 28775 F...

Page 8: ...o 44135 Include your name address and telephone number and include details concerning the claim Also supply us with the purchase date and the name and address of the dealer from whom you purchased our...

Page 9: ...auffage teignez toute flamme nue Fermez l alimentation en gaz l appareil L entretien doit tre effectu par un fournisseur de services d entretien qualifi Cet appareil de chauffage portatif aliment au g...

Page 10: ...DES PARTICULES DE POUSSI RE OU DES PRODUITS CHIMIQUES INCONNUS AVERTISSEMENT LE MONOXYDE DE CARBONE PEUT VOUS TUER L UTILISATION D UN CHAUFFAGE PORTABLE DANS UNE ZONE RECHARGEE PEUT PRODUIRE DU MONOXY...

Page 11: ...ilisez uniquement une alimentation au propane LIMINATION DES MANATIONS Si vous avez des questions propos de l limination des manations consultez votre d taillant de gaz propane 5 Installez les bonbonn...

Page 12: ...air de ventilation Consultez la rubrique portant sur les sp cifications techniques dans le manuel de l appareil ou sur la plaque de donn es de l appareil ou communiquez avec le fabricant pour obtenir...

Page 13: ...ppareil de chauffage Il ne se produit pas d arr ts impr vus ou inexpliqu s de l appareil La liste des pi ces et le sch ma de c blage pr sentent l appareil de chauffage tel qu il a t construit N utilis...

Page 14: ...ue au bas du tableau 2 D placez vous en ligne droite vers le haut jusqu au temps de fonctionnement souhait c t gauche du tableau 3 Notez la dimension de la bonbonne requise Tous les appareils de chauf...

Page 15: ...au point de charge 1 16 26122 Connexion raccord m le 3 8MPT x 3 8 SAE FLR 1 17 26101 lectrovanne Goyen 1 18 28775 Raccord troit 1 19 28777 Soupape de r glage du taux de combustion 1 20 28776 Raccord c...

Page 16: ...ous galement la date d achat et le nom et l adresse du d taillant de qui vous avez achet le produit Ce qui est nonc ci dessus constitue la responsabilit totale de l entreprise Il n existe aucune autre...

Page 17: ...ado por una agencia de reparaci n calificada Este calentador port til a gas no tiene una fuente propia de ventilaci n Utiliza el aire ox geno del rea en la cual se emplea Debe suministrarse el aire ne...

Page 18: ...IONES NUNCA USE EL CALENTADOR EN ESPACIOS QUE CONTIENEN O PODR AN CONTENER COMBUSTIBLES VOL TILES O PRODUCTOS COMO GASOLINA SOLVENTES DILUYENTE DE PINTURA O PRODUCTOS QU MICOS DESCONOCIDOS ADVERTENCIA...

Page 19: ...de propano con RECUPERACI N DE VAPOR Si tiene alguna pregunta sobre la recuperaci n de vapor consulte al proveedor de propano 5 Monte los cilindros de propano verticalmente v lvula hacia arriba Aseg...

Page 20: ...nga del aire que necesita para la combusti n Consulte la secci n de especificaciones del manual del calentador la placa del calentador o p ngase en contacto con el fabricante para conocer los requerim...

Page 21: ...re la salida de gas en el cilindro o los cilindros de suministro de gas LP cuando no est utilizando el calentador 4 Cuando deba guardar el calentador en un lugar cerrado deber desconectar la conexi n...

Page 22: ...al hasta encontrar el tiempo de funcionamiento deseado a la izquierda del gr fico 3 Lea el tama o de cilindro requerido Todos los calentadores deben tener cilindros llenos buena circulaci n de aire ci...

Page 23: ...ula de flujo en exceso POL 1 16 26122 Conexi n del acople macho 1 3 8 MPT x 3 8S AE FLR 17 26101 V lvula del solenoide Goyen 1 18 28775 Uni n de cierre del acople 1 19 28777 V lvula de ajuste de la ta...

Page 24: ...tamento de mantenimiento Mr Heater Inc 45125 W 1125 TH ST CLEVELAND OHIO 44135 Incluya su nombre direcci n y n mero de tel fono as como los detalles relativos al reclamo Adem s inf rmenos la fecha de...