30
• RELAY OUT
This function can operate only when the relay output setup has the time in the alarm menu.
Example:
RELAY OUT SETUP
OUT:
ALARM
OUT:
MIN
OUT3:
ALARM
OUT4:
5 MIN
EXIT (ESC TO EXIT)
You can select OUT or OUT4 and press
CTRL
or
IRIS OPEN
then that relay operates during the setting time only.
4.15 Motion Setup
The motion detection function is available in the preset mode only. After you set the motion in any preset, when you call the preset with the motion, the motion
detection operates.
In the preset setup, you can set the motion setup as below.
To enable the motion on the preset, set MOTION to
ON
.
To enter the MOTION SETUP, push the
joystick
to right on the MOTION SETUP.
PRESET SETUP
NUMBER:
00
TITLE:
– – –
CAMERA SET
DWELL:
– – – SEC
3 4 5 6 7 8 9 0 3 4 5 6 7 8 9 0
00 * * – – – – – – – – – – – – – – – – –
0 – – – – – – – – – – – – – – – – – – – –
04 – – – – – – – – – – – – – – – – – – – –
06 – – – – – – – – – – – – – – – – – – – –
NEXT PAGE
SAVE AND EXIT (ESC TO CANCEL)
PRESET CAMERA SETUP
FOCUS:
AUTO
MOTION:
OFF
MOTION SETUP
AE SETUP
SAVE AND EXIT (ESC TO EXIT)
MOTION SETUP
SENSITIVITY:
POSITION:
ALL
DELAY:
00SEC
OUTPUT:
OFF
HOLD TIME
03SEC
EXIT (ESC TO EXIT)
SENSITIVITY
-0
POSITION
ALL, CENTER (the center box displays): motion detection area.
DELAY
00-05SEC:
The delay time is used to make adjustments for scenes that have sudden changes such as lights and shadows
created by headlights of nearby traffic. The motion action occurs only when the motion keeps continuously during
the delay time.
OUTPUT
OFF, OUT, OUT, OUT3, OUT4: relay output
HOLD TIME
03-99SEC:
The hold time starts to count after the motion detects.
When a motion occurs, the dome activates the relay output, displays the message of „MOTION” on the screen, and sends the command of „ALARM 8” to the
keyboard.