3
AUTO SCAN SETUP
NUMBER
: 0
TITLE
: A0
MODE
: NORMAL
SPEED
: 5 STEP
START ANGLE
: – – – – – – – – – – – – –
END ANGLE
: – – – – – – – – – – – – –
SCAN DIR
: CCW
SWAP
: OFF
DWELL
: 03 SEC
SAVE AND EXIT (ESC TO CANCEL)
4.4 Auto Scan
(Shortcut:
Scan
)
The Auto scan supports up to 7 programmed angles at user-programmable speeds. Follow these steps to program Auto Scan:
NUMBER
0-08, 0-7,
09
: AUTO PAN mode
TITLE
up to characters
MODE
NORMAL, VECTOR, RANDOM (AUTO PAN mode: NORMAL, RANDOM only)
NORMAL: Move from start point to end point in panning only.
VECTOR: Move from start point to end point including tilt and zoom simultaneously and linearly. In some models, the zoom is fixed at wider
angle and the zoom magnification information is not displayed.
RANDOM: Move randomly between the start point and the end point.
SPEED
- 3 step, the lower number means the slower speed.
SCAN DIR
Set the scan direction, CCW (Counterclockwise), CW (Clockwise)
SWAP
Swap the start point for the end point.
DWELL
Set the dwell time in the tour mode, 0 – 99 seconds
. Press the
Scan
key to enter AUTO SCAN menu directly. Or press the
Menu
key to display the main menu on the monitor. Scroll to AUTO SCAN and push
the
Joystick
to the right.
. Select the „NUMBER” and set the desired number by pushing the
Joystick
left or right.
3. Select the „TITLE” and twist the
Joystick
to enter the title edit mode.
4. Twist the
Joystick
by changing the alphanumeric characters and move the next position. Or move down to the character table and press
CTRL
or
IRIS OPEN
at the desired character then the cursor position moves to the next position automatically. Push the
Joystick
left or right at the „ALL DELETE”
field to delete all characters. Push the
Joystick
left or right at the „EXIT” field to finish title edit menu.
TITLE EDIT MENU
A0
*
A B C D E F G H I J
K L M N O P Q R S T
U V W X Y Z 0 3
4 5 6 7 8 9 ( )
ALL DELETE
EXIT (ESC TO EXIT)
5. Select „MODE” and „SPEED”.
6. Select „START ANGLE”. Hold down the
CTRL
key while selecting the start position using the
Joystick
. Current panning position will be displayed. Release
CTRL
key to complete the selection of the start position. Or Press
IRIS OPEN
then the „CTRL” displays. Move the desired position and the zoom position.
Press
IRIS CLOSE
then the „CTRL” disappears. To adjust at the 0. degree interval, twist the
Joystick
at the pan field and the tilt field. To adjust at the
one zoom interval, twist the
Joystick
at the zoom field.
7. Select „END ANGLE.” Hold down the
CTRL
key while moving the Joystick to select the end position. The end position angle should be larger than start
position. Release the
CTRL
key to complete the selection of the end position. Or Press
IRIS OPEN
then the „CTRL” displays. Move the desired position
and the zoom position. Press
IRIS CLOSE
then the „CTRL” disappears. To adjust at the 0. degree interval, twist the
Joystick
at the pan field and the tilt
field. To adjust at the one zoom interval, twist the
Joystick
at the zoom field.
8. Set „SCAN DIR” to CCW or CW.
9. Select „SWAP”. Set to ON, to exchange the start angle and the end angle.