3.6 Setting Dome Camera Protocol
If a dome camera is to be installed with a Fastrax keyboard controller, select the default protocol.
Consult service personnel if a dome camera is installed with device other than a keyboard controller.
Figure 0 - Protocol Selection Switches
D11
Parity Bit
S6-3
Off
None
On
Even
S/W
On
Off
Function
D
S4-
Enable
Disable
Alarm
D
S4-
PAL
NTSC
NTSC/PAL
D3
S4-3
(Reserved)
D4
S4-4
RS-4
RS-485
RS-4/RS-485
D5
D6
D7
D12
Protocol
S5-1
S5-2
S5-3
S6-4
Off
Off
Off
Off
F, FE, Pelco-D, Pelco-P:
Default
Off
Off
On
Off
F, FE
Off
On
Off
Off
Sensormatic RS-4
Off
On
On
Off
Pelco-D, Pelco-P
On
Off
Off
Off
Vicon
On
Off
On
Off
Ernitec
On
On
Off
Off
(Reserved)
On
On
On
Off
F
Off
Off
Off
On
Philips (Bosch)
Off
Off
On
On
(Reserved)
Off
On
Off
On
Dynacolor
Off
On
On
On
(Reserved)
D8
D9
D10
Baud Rate
S5-4
S6-1
S6-2
Off
Off
Off
400 bps
Off
Off
On
4800 bps
Off
On
Off
9600 bps
(Default)
Off
On
On
900 bps
On
Off
Off
38400 bps