background image

Quick Installation Guide

Fastrax III

1/4” Day/Night Dome Camera, PTZ, 37x
EDC-3371

Summary of Contents for EDC-3222B

Page 1: ... Quick Installation Guide Fastrax III 1 4 Day Night Dome Camera PTZ 37x EDC 3371 ...

Page 2: ... 6 Setting Dome Camera Protocol 10 3 7 Connections 11 3 8 Getting Started 11 4 Program and Operation 12 4 1 Dome Camera Selection 12 4 2 Accessing On Screen Menu Utility 12 4 3 How to control On Screen Menu Utility 12 4 4 More Information 12 5 Short Cut Key 13 6 Specifications 14 7 Dimensional Drawings 16 NOTE The full manual is only available in English Komplette Betriebsanleitung Full Manual Mod...

Page 3: ...laying the cable in such a way that the cable does not act as a gutter During assembly care must be taken to ensure that existing seals are correctly inserted and are not displaced as a result of assembly You must not continue to use damaged seals NOTE This is a class A digital device This digital device can cause harmful interference in a residential area in this case the user may be required to ...

Page 4: ...tside caution should be taken to avoid vibration and shaking of Fastrax dome due to windload or shock of passing heavy vehicles If pole is not stable enough it may cause malfunction in accurate tilt positioning up to 255 multiplexers Alarm Input up to 8 Sensor Siren Flashing light Alarm Output up to 4 up to 99 DVRs up to 254 cameras including 64 alarm modes push push remove camera window bubble ri...

Page 5: ...h body and base of the camera Different version will not support alarm input and output The dome camera is for use in surface mounting applications and the mounting surface should be capable of supporting loads up to 4 5kg The dome camera s base should be attached to a structural object such as a hard wood wall stud or ceiling rafter that supports the weight of the dome camera Figure 3 Installatio...

Page 6: ...m should be installed according to Figures 4 through 9 Power 24VAC STP AWG 24 Sensor Alarm input up to 8 Siren Light Alarm output up to 4 BNC Alarm output 1 2 Alarm input 1 4 Power 24VAC Dome1 Dome1 Alarm output 3 4 Alarm input 5 8 Monitor RS 485 Half Duplex mode RX TX RX TX RS 422 Simplex mode RX RX Duplex mode RX TX RX TX RX RX Rear Master Keyboard controller J Box Dome RS485 DOME1 RX TX RS485 D...

Page 7: ...unication terminated by setting the appropriate DIP switch Without proper termination there is potential for control signal errors Total length of the cable for communication should not exceed 1 2km SW1 1 2 Terminated ON ON Not terminated OFF OFF Figure 6 Setting Dome Camera Termination SW1 Termination switches SW2 Fail Safe Network Addresses ID and protocol selection switches 1 2 ON SW1 ...

Page 8: ...mmunication Cable for communication Termination ON 1 2km 3 4 Fail safe Network When you control the dome by the other device not own keyboard some error may be existed in the serial communication The reason is caused by the other device without the fail safe network At this time you solve the problem to set this DIP switch to ON of the nearest dome from the other device only SW2 1 2 ON PULL UP PUL...

Page 9: ...ess more than 999 you should connect the service provider Example Port 1 Dome 1 Port 2 Dome 2 Port 16 Dome 16 If more than 16 dome cameras are installed using two or more multiplexers ID of the dome camera should be ID of MUX x No of camera IN e g multiplexer ID n Camera IN m then ID of Dome 16x n 1 m Refer to Figures 4 5 for setting the dome camera address ID and protocol selection Figure 9 Setti...

Page 10: ...PAL NTSC NTSC PAL D3 S4 3 Reserved D4 S4 4 RS 422 RS 485 RS 422 RS 485 D5 D6 D7 D12 Protocol S5 1 S5 2 S5 3 S6 4 Off Off Off Off F2 F2E Pelco D Pelco P Default Off Off On Off F2 F2E Off On Off Off Sensormatic RS 422 Off On On Off Pelco D Pelco P On Off Off Off Vicon On Off On Off Ernitec On On Off Off Reserved On On On Off F2 Off Off Off On Philips Bosch Off Off On On Reserved Off On Off On Dynaco...

Page 11: ...e connectors marked GND are common Connect the ground side of the Alarm input and or alarm output to the GND connector NC NO 1 TO 4 Normal Close or Normal Open Alarm Out The dome camera can activate external devices such as buzzers or lights Connect the device to the NC NO Alarm Out and COM Common connectors See Chapter 3 Program and Operation for configuring alarm output Connecting the Power Conn...

Page 12: ...On screen menu utility will appear 4 3 How to control On Screen Menu Utility Button Function MENU Call on On screen menu utility Joystick up or down Navigate through the menu items Joystick left or right or IRIS OPEN Go into the sub menu items Joystick left or right or Zoom handle twist or Tele Wide Change value Enter the editing title mode CTRL Joystick Change value of angle IRIS OPEN Enter the c...

Page 13: ...uto mode 12 ON Digital Zoom ON According to digital zoom setting 12 OFF Digital Zoom OFF 13 ON Dome OSD ON 13 OFF Dome OSD OFF 14 ON Dome Area Title Display ON 14 OFF Dome Area Title Display OFF 15 ON View Direction ON 15 OFF View Direction OFF 100 ON Shutter speed auto 101 ON Shutter speed 1 4 PAL 1 3 sec 102 ON Shutter speed 1 2 sec 103 ON Shutter speed 1 sec 104 ON WDR ON 104 OFF WDR OFF 105 ON...

Page 14: ...IR cut filter switchable Day night switching auto On Off global Privacy zones 8 zones masking with block or video OFF option Menu languages German English French Spanish Italian Portugese Polish OSD function control 4 3 16 9 compression zoom 4 3 format only BIB video A B or Y C Text display 12 character labels Activity detection yes Motion detector in preset mode only Mirror function 180 rotation ...

Page 15: ...p function rotates dome 180 at bottom or tilt travel Home position included Auto calibration yes Presets 240 presets with camera status 12 character title display Illumination no External connections Video BNC RS 485 RS 422 alarm output alarm input Serial interfaces RS 422 RS 485 Interface protocols Fastrax IIE Pelco D Pelco P Sensormatic RS 422 Vicon Ernitec Bosch Dynacolor Housing material plast...

Page 16: ...alised trade channels only VIDEOR E Hartig GmbH Carl Zeiss Straße 8 63322 Rödermark Germany Tel 49 0 6074 888 0 Fax 49 0 6074 888 100 www videor com www eneo security com Technical changes reserved Copyright by VIDEOR E Hartig GmbH 05 2012 7 Dimensional Drawings Dimensions mm 199 202 45 R2 3 R5 ...