Endura FSTL1000 Operator'S Manual Download Page 4

1

www.uniquip.ca

Thank you for your purchase of the Uniquip Endura FSTL1000 Portable

Tower Light. This tower light has been designed and manufactured to our
highest quality demands for durability and performance.

Uniquip Canada Inc. is committed to offering durable products and

quality after-market service. The FSTL1000 Portable Tower Light is warranted
to be free from manufacturer's defects in material and workmanship for a
period of

one (1) year

from the date of shipping as declared on the invoice

from Uniquip Canada. This warranty will be void if the light tower has not
been operated and maintained in the manner prescribed in this Operator's
Manual.

In order for the tower light to perform at its optimum capabilities, the

operator of the unit

must read

this manual

thoroughly before

using this

unit. This Operator's Manual contains important product operation
procedures, and safety precautions.

SAVE THIS MANUAL.

Please keep

this manual nearby when operating the tower light as a reference should any
questions arise.

This tower light is a high voltage electrical device.

DO NOT start

this unit unless it is clear of water or water-filled areas. DO NOT
use this tower light with non-grounded sockets. Use this light
only with GFCI protected circuits. This product is designed for
normal outdoor use.

All jobsites are different. Please ensure that when installing this tower

light in a jobsite, proper precautions have been taken to avoid any accidents,
and to reduce the risk of fire, electric shock or personal injury.

Every care and effort has been made to ascertain the accuracy and

completeness of procedures described in this document to ensure your
enjoyment and satisfaction. If you have any questions or concerns, please
contact the Service Department at Uniquip Canada at 1-800-332-4012.

Pre-Operation Notes

Technical Support Hotline

Ontario,

Western Canada, and USA

T : 1-888-332-4012
F : 1-866-567-0956

Quebec

and Eastern Canada

T : 1-800-332-4012
F : 1-866-825-2221

email your technical questions and comments to:

[email protected]

visit our website:

www.uniquip.ca

2

www.uniquip.ca

1.

READ AND UNDERSTAND OPERATOR'S MANUAL PRIOR TO USE

OF TOWER LIGHT.

2.

THE LIGHTED LAMP IS HOT. DO NOT TOUCH LIGHT FIXTURE,

REFLECTOR OR LENS DURING USE. WAIT FOR AT LEAST 10
MINUTES AFTER SHUT-DOWN TO BE IN CONTACT WITH LAMP.

3. Make certain that the power source conforms to the requirements of your

equipment.

NEVER ALTER THE PLUG.

4.

DO NOT

plug pump into any

NON-GROUNDED

electrical outlet.

5.

DO NOT

attempt to remove ground stem on plug.

6.

USE ONLY

on GFCI protected circuits.

7.

MAKE SURE OPERATOR, CABLE, PLUG AND SOCKET ARE ALL

DRY AND CLEAN. LIQUIDS AND ELECTRICITY DO NOT MIX.
CHEMICALS AND ELECTRICITY DO NOT MIX.

8.

DO NOT

operate where water may accumulate around base.

9.

DO NOT

submerse any portion of the FSTL-1000MH Tower Light in liquid.

10. Keep light

AT LEAST 16' FT AWAY

from pools and spas.

11. Keep light away from any flammable materials.
12.

DO NOT

perform any repairs or maintenance procedures on tower light

unless it has been disconnected from any power source.

13. Use only Endura brand-name parts.
14.

ALL

frayed and/or otherwise damaged cords and components

MUST

be replaced before further use.

15. When using in windy and or other difficult weather conditions, set tower

light up such that the wind is at the back of the fixture and apply the
brake. Support with sand bags if necessary.

16. If light is extended higher than 6' ft,

anchor base to ground

.

17. Always ensure that tires are filled up at proper tire pressure.
18. Always set brake on tower light for transport or when tower light will

be left unattended.

19. Never use any light bulbs larger than what the fixture is rated for.
20.

NEVER LOOK DIRECTLY INTO LIGHTED LAMP.

21.

NEVER OPERATE THE FIXTURE WITHOUT SAFETY LENS

. If safety

lens is broken, replace lens prior to operating fixture.

22. Keep fixture away from children.
23.

DANGER: HIGH VOLTAGE!

24. Provide adequate protection and guarding of all movable parts.

SAVE THESE INSTRUCTIONS.

Safety Precautions

Summary of Contents for FSTL1000

Page 1: ...AD ALL the sections in this manual PRIOR to attempting to service maintain or operate this equipment Copyright Uniquip Canada 2004 All rights reserved DO NOT operate this equipment until you have read and understood all the enclosed Operator s Manual ...

Page 2: ...erable Uniquip Canada Inc s liability under warranty is limited to repair of the product and or replacement of parts and is given to the purchaser in lieu of all other remedies including incidental and consequential charges There are no expressed warranties other than those specified herein Endura Warranty Statement Endura Warranty Summary Protection 1 Uniquip Endura Tower Light Unit 1 year parts ...

Page 3: ...n or operate this equipment Copyright Uniquip Canada 2004 All rights reserved DO NOT operate this equipment until you have read and understood all the enclosed Operator s Manual Pre Operation Note 1 Safety Precautions 2 Guide to Machine Overview 3 Machine Overview 4 Parts List 5 Key Components Overview 6 7 8 9 10 Contents List 11 Setting up the FSTL1000 12 13 Pre Operation Procedures 14 Operation ...

Page 4: ...66 567 0956 Quebec and Eastern Canada T 1 800 332 4012 F 1 866 825 2221 email your technical questions and comments to service uniquip ca visit our website www uniquip ca 2 www uniquip ca 1 READ AND UNDERSTAND OPERATOR S MANUAL PRIOR TO USE OF TOWER LIGHT 2 THE LIGHTED LAMP IS HOT DO NOT TOUCH LIGHT FIXTURE REFLECTOR OR LENS DURING USE WAIT FOR AT LEAST 10 MINUTES AFTER SHUT DOWN TO BE IN CONTACT ...

Page 5: ...ce or repair procedures please contact our Technical Support Hotline for clarification and to acquire appropriate parts To order spare parts please provide the following information 1 Machine Make 2 Model Number 3 Machine Serial Number 4 Quantity Required of Each Part 5 Part Numbers 6 Part Descriptions All Endura parts are guaranteed by a thirty 30 day warranty against any manufacturer s defects i...

Page 6: ...echnician is qualified and clear on the task s requirements Legend Part Number Description 1 FSTL1000 01 Fixture 2 FSTL1000 02 Reflector 3 FSTL1000 03 Lens Clips 4 FSTL1000 LENS Lens Kit 5 FSBD BULB1000 1000 W Metal Halide Lamp 6 FSTL1000 06 U Bracket 7 FSTL1000 07 Mast 8 FSTL1000 08 Cart 9 FSTL1000 BRAKE Brake Kit 10 FSTL1000 10 Wheels 11 FSTL1000 11 Ballast Not shown See Key Components Overview ...

Page 7: ...STL1000 03 Lens Clip available separately 15 FSTL1000 15 Lens Frame 16 FSTL1000 16 Lens 17 FSTL1000 17 Silicone Rubber Seal 18 FSTL1000 18 Security Cable 19 FSTL1000 19 Components of Fixture FSTL1000 01 20 FSTL1000 20 21 FSTL1000 21 22 FSTL1000 22 23 FSTL1000 23 24 FSTL1000 24 25 FSTL1000 25 Silicone Rubber Ring 26 FSTL1000 26 Metal Ring 27 FSTL1000 27 Security Chain Components of Lens Kit FSTL100...

Page 8: ...re components of the following kits are not available separately unless otherwise stated FSTL1000 LENS Lens Kit Part Number Description FSTL1000 15 Lens Frame FSTL1000 16 Lens FSTL1000 17 Silicone Rubber Seal FSTL1000 18 Security Cable FSTL1000 27 Security Chain FSTL1000 BALLAST Ballast Assembly FSTL1000 11 Ballast available separately FSTL1000 12 Ballast Lid FSTL1000 13 Ballast Box FSTL1000 28 Ru...

Page 9: ...ces the operator Remove and put aside washers from metal feet and brake Keep rubber supports on metal feet Figure 1 Figure 1 2 Flip cart over ballast box and line up ballast support bars to metal feet Tighten ballast to cart with washers from metal feet and brake Figure 2 Figure 2 4 Place rubber ring on fixture Make sure that the ring is correctly aligned to markers on fixture Figure 4 Figure 4 5 ...

Page 10: ... for the personal and property safety of the operator and jobsite 1 Before operating the light ensure that it is structurally and mechani cally safe by checking the following a Inspect that all the sections of the Tower Light are properly installed as per the guidelines in the section Setting up the FSTL1000 i Is the mast securely bolted into the mast support ii Is the floor brake being used for f...

Page 11: ... vertical position and slide pin back in place 5 When adjusting the light fixture always make sure that the fixture is COOL before adjusting Aim the fixture approximately 15 above desired level Tighten knobs lightly to hold fixture in place then pull fixture down to desired level Completely tighten knobs to secure fixture 6 To raise the telescopic mast grasp upper mast firmly and raise the post un...

Page 12: ...hts reserved Technical Support Hotline Ontario Western Canada and USA T 1 888 332 4012 F 1 866 567 0956 Quebec and Eastern Canada T 1 800 332 4012 F 1 866 825 2221 email your technical questions and comments to service uniquip ca visit our website www uniquip ca ...

Page 13: ...FSTL1000 08 Cart Wheel Base FSTL1000 10 Wheel with bolt and washer FSTL1000 BRAKE Brake Kit FSTL1000 41 Cart Wheel Base ...

Page 14: ...FSTL1000 14 4m Electrical Connection Cord FSTL1000 BALLAST Ballast Assembly FSTL1000 58 Power Cord FSTL1000 CAPACITOR Capacitor FSTL1000 31 Electrical Switch includes boot and ON OFF plate ...

Page 15: ...FSTL1000 01A Electrical Components for Fixture FSTL1000 23 Ceramic Element FSTL1000 01 Fizture Casing ...

Page 16: ...000 02A Spacer Kit for Reflector FSTL1000 03 Lens Clip sold individually FSTL1000 18 Security Cable FSTL1000 27 Safety Chain Clip FSTL1000 41 Knobs FSTL1000 LENS Complete Lens Kit Includes glass lens silicone ring aluminum frame ...

Page 17: ...FSTL1000 38 Bracket Pin FSTL1000 33 Bracket Mount FSTL1000 06 U Bracket FSTL1000 39 O Pin FSTL1000 35 Shock Absorber sold individually FSTL1000 36 Washer FSTL1000 37 Nut FSTL1000 39 O Pin ...

Page 18: ...FSTL1000 APK Y Mast Adjustment Pin for FSTL1000Y ONLY FSTL1000 APK Mast Adjustment Pin for FSTL1000 ONLY FSTL1000 07 Mast for FSTL1000 ONLY FSTL1000 07 Y Mast for FSTL1000Y ONLY ...