11
fastened condition. The counter-hood must
cover the protection for the cardan joint over a surface of at least 50 mm
and prevent intentionanal contact of the hands with
elements which are moving
.
b) align the generator shaft and the cardan joint with the tractor's drive so that
they are linear.
c) the three anchoring points provided are fastened
perfectly
and secured by the fastening elements provided.
2.
For the first commissioning oil must be poured into the transmission unit
and changed after the first 50 operating hours;
check the level afterwards. For the version
with the level indicator the oil level must lie approximately
in the middle. For the version without a level indicator loosen the
lower side plug until one can sense oil coming out
. If the level is too low oil must be added through the
opening in the upper section of the transmission unit
. For a rapid and complete change of oil we
recommend unscrewing both the lower and the upper plug
on the body of the transmission unit. We draw your attention to the fact that
only oil for gearwheels type
SAE, 90EP may be used. Disposal of the old oil
should only be over specialist centres and by
observing the pertinent valid national regulations.
3.
Before commissioning one must check that all connections are be in a perfect
condition
and that there should be no hindrances which
could impair rotation of the moving parts,
. Ensure that the suction in and und ejection openings
for cooling are free.
4.
Abide by applicable safety standards for electrical connections.
Abide by the safety standards. Check that the
details on the nameplate correspond to the characteristics of
system to which the machine is to be connected.
-----------------------------------------------------------------------------------------------------------
The device must be earthed by connecting an earthing rod to the frame's
earthing terminal
(only in combination with RCD)
.
5.
Check that the switch is in the OFF position and
both the generator and the tractor have all
safety equipment installed and that it is fully functional. Abide by the safety
standards. Check that the details on the nameplate correspond to the
characteristics of the system to which the machine is to be connected.