Troubleshooting
66
ESE 406 - 606 (D)HG-GT (ES) Duplex
Status: August 2017
7.
Troubleshooting
This section describes problems during operation that au-
thorized personnel can remove.
Each occurring problem is described with its possible cause
and the respective corrective measure.
The authorised personnel must immediately shut down the
generator and inform the responsible and authorised service
personnel if a problem cannot be solved with the aid of the
following table.
Malfunction
Possible cause
Correction
No or insufficient voltage
available during idling.
The rotational speed of the
engine was adjusted after-
wards.
Call service staff.
The electronic controller has
been altered. (for ESE 606
DHG-GT (ES) Duplex
Call service staff.
The electronic controller is de-
fective. (for ESE 606 DHG-GT
(ES) Duplex
Call service staff.
Strong voltage fluctuations
occur.
The engine runs irregularly.
Call service staff.
The speed control works er-
ratically or insufficiently.
Call service staff.
The engine does not start.
The engine is being operated
incorrectly.
Follow the engine operating
manual instructions.
Maintenance of the engine
was inadequate.
Follow the engine mainte-
nance instructions.
Too little fuel in the tank.
Refuel
The fuel filter is clogged.
Replace the fuel filter.
Bad fuel in the tank.
Call service staff.
The ignition cable does not
have any connection to the
spark plug.
Attach ignition cable to the
spark plug.
The choke is not activated in
a cold condition.
Actuate choke.
The engine does not rotate.
Engine defective.
Call service staff.
The engine smokes.
Too much oil in the engine.
Drain excess oil.
Paper element of the air filter
is dirty or oil-soaked.
Clean paper element or re-
place if necessary.
Summary of Contents for ESE 406 HG-GT ES DUPLEX
Page 12: ...General information Safety symbols 12 ESE 406 606 D HG GT ES Duplex Status August 2017 Notes...
Page 53: ...Operation Disposal Status at August 2017 ESE 406 606 D HG GT ES Duplex 53 Notes...
Page 68: ...Troubleshooting 68 ESE 406 606 D HG GT ES Duplex Status August 2017 Notes...
Page 75: ...Written guarantee Status at August 2017 ESE 406 606 D HG GT ES Duplex 75 10 Written guarantee...
Page 76: ...Written guarantee 76 ESE 406 606 D HG GT ES Duplex Status August 2017...
Page 77: ...Written guarantee Status at August 2017 ESE 406 606 D HG GT ES Duplex 77 Notes...