Function und operating principle
The synchronous generator is firmly coupled to the drive en-
gine. The aggregate is installed in a stable frame with a cover
hood and equipped with flexible and low vibration suspension
elements.
Splash-proof earthed power and CEE sockets with a nominal
voltage of 230 and/or 400 V/50 Hz supply the power.
An integrated voltage regulator controls the voltage of the
generator in the nominal speed range of the generator.
The generator is designed for mobile operation with one or
more electrical consumers (safety-separated circuit according
to VDE 100, Part 551). The protective conductor of the ground
contact socket assumes the function of the potential equalisa-
tion line.