Status at:
February 2013
ESE 807 / 1107 / 1307 / 1407 DBG (ES) DIN
31
Function and mode of operation
3.2
The synchronous generator is firmly coupled to the drive
engine. The assembly is installed in a stable frame and
equipped with a flexible, low-vibration suspension.
Splash-proof, shockproof and CEE sockets with a nominal
voltage of 230V and/or 400V / 50 Hz supply the power.
On some models the engine rotational speed control (cen-
trifugal governor ) is supported at high loads by a special
performance management module (Maxdrive).
An integrated voltage regulator controls the voltage of the
generator in the nominal speed range of the generator.
The generator is designed for mobile operation with one or
several electrical consumers (safety-separated circuit ac-
cording to VDE 100, Part 551). The protective conductor of
the ground contact socket assumes the function of the po-
tential equalisation line.