Solitrend MMP60
Electrical connection
Hauser
11
A
B
C
D
E
F
G
H
J
K
A0037415
4
Assignment of the 10-pin plug
A
12 to 24 V
DC
stabilized power supply
Wire color: red (RD)
B
0 V
DC
power supply
Wire color: blue (BU)
D
1st analog positive (+), material moisture
Wire color: green (GN)
E
1st analog return line (-), material moisture
Wire color: yellow (YE)
F
RS485 A (must be enabled)
Wire color: white (WH)
G
RS485 B (must be enabled)
Wire color: brown (BN)
C
IMP-Bus RT
Wire color: gray (GY) / pink (PK), see figure below
J
IMP-Bus COM
Wire color: blue (BU) / red (RD), see figure below
K
2nd analog positive (+)
Wire color: pink (PK)
E
2nd analog return line (-)
Wire color: gray (GY)
H
Shield (is grounded at the device. The installation must be grounded correctly!)
Wire color: transparent
6.3
Post-connection check
Is the device or cable undamaged (visual inspection)?
Does the supply voltage match the specifications on the nameplate?
Are the connections established correctly and protected against mechanical influences?