Operating Instructions

Solitrend MMP40

Material moisture measurement

BA01936M/00/EN/02.19

71454834

2019-10-31

Summary of Contents for Solitrend MMP40

Page 1: ...Products Solutions Services Operating Instructions Solitrend MMP40 Material moisture measurement BA01936M 00 EN 02 19 71454834 2019 10 31...

Page 2: ...Solitrend MMP40 2 Endress Hauser Order code Ext ord cd Ser no www endress com deviceviewer Endress Hauser Operations App XXXXXXXXXXXX XXXXX XXXXXX XXX XXXX XX Serial number 1 3 2 A0023555...

Page 3: ...5 6 Protection of sensor connector against abrasion 14 5 7 Post installation check 15 6 Electrical connection 16 6 1 Connection conditions 16 6 2 Cable specification 18 6 3 Electrical connection exam...

Page 4: ...erious or fatal injury WARNING This symbol alerts you to a dangerous situation Failure to avoid this situation can result in serious or fatal injury CAUTION This symbol alerts you to a dangerous situa...

Page 5: ...nt Endress Hauser 5 Notice or individual step to be observed 1 2 3 Series of steps Result of a step 1 2 3 Item numbers A B C Views Safety instructions Observe the safety instructions contained in the...

Page 6: ...Endress Hauser website www endress com downloads For an overview of the scope of the associated Technical Documentation refer to the following W M Device Viewer www endress com deviceviewer Enter the...

Page 7: ...tructions in the Installation section The operation of the devices does not present any health risk If the limit values specified in the Technical data and the conditions listed in the manual and addi...

Page 8: ...s pertaining to repair of an electrical device Use original spare parts and accessories from the manufacturer only Hazardous area To eliminate a danger for persons or for the facility when the device...

Page 9: ...erial moisture sensors for measuring bulk solids emulsions liquids and media with higher material densities and conductivity values up to 20 ms cm 3 1 Product design 1 2 3 1 2 3 1 2 3 1 2 3 A0040142 1...

Page 10: ...of the device features on the delivery note Enter the serial number from the nameplates into W M Device Viewer www endress com deviceviewer All the information about the measuring device and the scop...

Page 11: ...l covering the cell must be 35 mm moisture dependent The flow of material over the surface of the sensor should be relatively continuous Depending on the operating mode the electronics module offers w...

Page 12: ...gths and can be ordered together with the device via the Accessory mounted option NA or Accessory enclosed option PA section of the product order structure 2 Make the cut out in the container 5 3 Moun...

Page 13: ...1 8 5 0 33 12 5 0 49 25 0 98 47 5 1 87 45 1 77 A0037426 5 Dimensions of rectangular sensor Unit of measurement mm in 5 5 Mounting location for rod sensor The rod sensor can be installed using a mounti...

Page 14: ...on the sensor before the mounting flange can be fixed The installation pipe is available in two different lengths and can be ordered together with the device via the Accessory mounted option NA or Ac...

Page 15: ...d ground cable can be protected with a silicone tube not included in the delivery A0037429 10 Example of round sensor 5 7 Post installation check Perform the following checks after mounting the device...

Page 16: ...or red RD B 0 VDC power supply Wire color blue BU D 1st analog positive material moisture Wire color green GN E 1st analog return line material moisture Wire color yellow YE F RS485 A must be enabled...

Page 17: ...ply voltage and bus interface C Connector for supply voltage and bus interface included in the delivery for remote display 1 0 VDC power supply Wire color blue BU 2 12 to 24 VDC stabilized power suppl...

Page 18: ...itive material moisture Wire color green GN 2 Rectangular sensor 6 2 Cable specification Connecting cables are available in different versions and lengths depending on sensor design Round sensor rod s...

Page 19: ...P Bus COM Wire color blue BU red RD 5 1st current output analog Wire color green GN 6 1st current output analog Wire color yellow YE 7 2nd current output analog Wire color pink PK 8 2nd current output...

Page 20: ...ns 7 1 Overview of operation options 1 2 3 4 6 5 7 8 9 IMP Bus RS485 A0037417 15 Operation options 1 Round sensor short 2 Round sensor middle 3 Round sensor long 4 Rectangular sensor 5 Rod sensor 6 Re...

Page 21: ...ge for conductivity Output 2 automatically switches between these two windows every 5 seconds 8 1 1 Therefore there are several possible settings for analog outputs 1 and 2 Analog outputs Options 0 to...

Page 22: ...ging and without filter functions and with up to 100 measurements per second internally and a cycle time of 250 milliseconds at the analog output CA mode Cyclic Average Filter Standard averaging for r...

Page 23: ...d The user can set the desired calibration curve which may have been modified by clicking the Set Default Calib button This curve is activated for measurement once the sensor power supply is switched...

Page 24: ...re value during moisture measurement In air the sensors measure approx 60 picoseconds radar transit time and 1000 picoseconds in water 8 4 Special functions 8 4 1 Determining the mineral concentration...

Page 25: ...nstant such as a temperature dependency only in very specific moisture ranges it may be necessary to perform complex material temperature compensation This involves a considerable amount of work in th...

Page 26: ...terial flow over the sensor In such cases it may be necessary to concentrate the material flow so that material accumulates above the sensor as it flows The diagram below shows an example of a possibl...

Page 27: ...l calibration curve Cal1 for sand and gravel Incorrect moisture scaling is configured in the PLC In the sensor 0 to 20 moisture corresponds to the 0 to 20 mA or 4 to 20 mA current output The 0 to 20 m...

Page 28: ...end MMP40 28 Endress Hauser 10 Maintenance No special maintenance work is required 10 1 Exterior cleaning When cleaning the exterior always use cleaning agents that do not corrode the surface of the s...

Page 29: ...ice return vary depending on the device type and national legislation For information on device return please see http www endress com support return material 11 3 Disposal If required by the Directiv...

Page 30: ...sensor cut out 108 mm Material 1 4301 Dimensions Length 300 mm 11 81 in Width 200 mm 7 87 in Height 6 mm 0 24 in 12 1 2 Universal holder with tilt mechanism for round sensor The universal holder for...

Page 31: ...metal for sliding carriage made of 1 4301 3 threaded bolts for fastening For installation on conveyor belts 12 1 4 Installation pipe 1 m for rod sensor The installation pipe for the rod sensor can be...

Page 32: ...Accessories Solitrend MMP40 32 Endress Hauser A0037580 23 Adapter set for rod sensor Material 1 4301 1 installation pipe extension D 55 mm L 0 2 m 1 adapter to D 76 2 mm L 80 mm...

Page 33: ...ns Moisture temperature Output 1 for moisture output 2 for material temperature Moisture conductivity Output 1 for moisture output 2 for conductivity in the range from 0 to 20 mS cm Moisture temperatu...

Page 34: ...ble to a certain degree The material temperature can be determined following an external calibration and compensation of the sensor s internal heating Maximum measured error The measured error depends...

Page 35: ......

Page 36: ...www addresses endress com 71454834 71454834...