Solicap M FTI55, FTI56
Technical data
Hauser
83
10.4.4
Degree of protection
* As per EN60529
** As per NEMA 250
*** Only with M20 cable entry or G1/2 thread
10.4.5
Vibration resistance
DIN EN 60068-2-64/IEC 68-2-64: 20 Hz– 2000 Hz; 0.01 g
2
/Hz
10.4.6
Cleaning
Housing
When cleaning, make sure that the cleaning agent used does not corrode the housing surface or the
seals.
Probe
Depending on the application, buildup (contamination and soiling) can form on the probe rod. A
high degree of material buildup can affect the measurement result. If the medium tends to create a
high degree of buildup, regular cleaning is recommended. When cleaning, it is important to make
sure that the insulation of the probe rod is not damaged. If cleaning agents are used make sure the
material is resistant to them!
10.4.7
Electromagnetic compatibility (EMC)
• Interference emission to EN 61326, Electrical Equipment Class B
Interference immunity in accordance with EN 61326, Appendix A (Industrial) and NAMUR
Recommendation NE 21 (EMC)
• A usual commercial instrument cable can be used.
10.4.8
Shock resistance
DIN EN 60068-2-27/IEC 68-2-27: 30g acceleration
IP66*
IP67*
IP68*
NEMA4X**
Polyester housing F16
X
X
-
X
Stainless steel housing F15
X
X
-
X
Aluminum housing F17
X
X
-
X
Aluminum housing F13
with gas-tight process seal
X
–
X***
X
Aluminum housing T13
with gas-tight process seal and
separate connection compartment
(EEx d)
X
–
X***
X
Separate housing
X
–
X***
X