6.2.12
Upload/download sensor DAT (EEPROM)
!
Note!
• The customer-specific settings of the electronic insert (e.g. empty/full calibration, switch point
adjustment) are stored automatically in the sensor DAT (EEPROM) and in the electronic insert.
• The sensor DAT (EEPROM) is updated automatically each time a parameter is changed in the
electronic insert.
• When replacing the electronic insert, all the sensor DAT (EEPROM) data are transferred to the
electronic insert by means of a manual upload. No additional settings are required.
• If, for example, you need to transfer the customer-specific settings of an electronic insert to
multiple sensor DATs (EEPROMs), you must carry out a manual download after installing the
electronic insert.
–
Upload:
An upload transfers the saved data from the sensor DAT (EEPROM) to the electronic
insert. The electronic insert does not have to be configured any more, and the device is then
operational.
–
Download:
A download transfers the saved data from the electronic insert to the sensor DAT
(EEPROM).
To carry out a sensor upload/download, proceed as follows:
1.
Turn the function switch to position 8.
2.
Press the "–" key for at least two seconds to carry out a download (the data from the electronic
insert are transferred to the sensor DAT (EEPROM).
During the download, the green LED 1 flashes.
3.
Press the "+" key for at least two seconds to carry out an upload (the data from the sensor DAT
(EEPROM) are transferred to the electronic insert).
The green LED 5 flashes during upload.
You have now transmitted the data and can turn the function switch back to position 1 (operation).
Function switch
position
Function
– key
+ key
Light emitting diodes (LED signals)
A
B
C
1 (green)
2 (green)
3 (red)
4 (green)
5 (green)
6 (yellow)
8
Upload/download sensor
DAT (EEPROM)
Press for
download
Press for
upload
Flashes
(download)
Flashes
(upload)
**
*
These settings are factory settings.
** Switch status signaling (on/off/flashing) depends on the mounting location selected and the failsafe mode (MIN/MAX) set.
The LED flashes if a calibration has not yet been carried out.