Operation
Prothermo NMT81
74
Hauser
Element temperature
Element temperature screen shows each element temperature and position. Confirm that
appropriate values are shown.
• 82: Element 1 to 24 position
• 83: Element 1 to 24 temperature
(82)
n (83)
(79)
(80)
(81)
(78)
3 (83)
2 (83)
1 (83)
(65)
0mm
A0044824
70
Element temperature
Element resistance
Element resistance shows each element resistance and position. Confirm each resistance
shows appropriate values.
A0044826
71
Element resistance screen
Elements in vapor/product
Elements in vapor/product shows the elements used for calculation of average vapor
temperature and average product temperature. All elements above the product level are
considered to be elements in vapor. Defective elements will be also skipped.
• 79: Elements in vapor
• 80: Elements in product
Summary of Contents for Prothermo NMT81