Proline Prowirl 200
XA01148D
Hauser
19
Terminal assignment
Transmitter
The order code is part of the extended order code. For detailed
information on the features of the device and the structure of the
Connection versions
Order code for
"Output"
Terminal numbers
Output 1
Output 2
Input
1 (+)
2 (-)
3 (+)
4 (-)
5 (+)
6 (-)
Option
A
4-20 mA HART
(passive)
-
-
Option
B
4-20 mA HART
(passive)
Pulse/frequency/
switch output
(passive)
-
Option
C
4-20 mA HART
(passive)
4-20 mA analog
(passive)
-
Option
D
4-20 mA HART
(passive)
Pulse/frequency/
switch output
(passive)
4-20 mA current
input (passive)
Option
E
FOUNDATION
Fieldbus
Pulse/frequency/
switch output
(passive)
-
Option
G
PROFIBUS PA
Pulse/frequency/
switch output
(passive)
-
1)
Output 1 must always be used; output 2 is optional.
2)
The integrated overvoltage protection is not used with option D: Terminals 5 and 6
(current input) are not protected against overvoltage.
3)
FOUNDATION Fieldbus with integrated reverse polarity protection.
4)
PROFIBUS PA with integrated reverse polarity protection.
Safety-related values
The order code is part of the extended order code. For detailed
information on the features of the device and the structure of the