Proline Prowirl 200
XA01148D
Hauser
17
2. Select the maximum medium temperature T
m
of this row, which
is larger or equal to the measured maximum medium
temperature T
mm
.
The column with the temperature class for gas is determined:
108 °C ≤ 130°C → T4.
3. The maximum temperature of the temperature class determined
corresponds to the maximum surface temperature for dust: T4 =
135 °C.
Connection data:
Signal circuits
The following tables contain specifications which are dependent on the
transmitter type and its input and output assignment. Compare the
following specifications with those on the nameplate of the transmitter.
Cable specification: Connecting cable for remote version
The sensor cable connection between the sensor and the transmitter
has Ex ia type of protection.
Cable parameter: L/R ≤ 38.2 μH/Ω
The cable supplied by Hauser complies with this value.
Connecting the transmitter
2
1
4
3
A0023831