Technicalйdata
ProlineйPromagйDй400йHART
128
Hauser
16.4 Output
Outputйsignal
Current output
Current output
Canйbeйsetйas:
• 4-20йmAйNAMUR
• 4-20йmAйUS
• 4-20йmAйHART
• 0-20йmA
Maximum output values
• DCй24йVйсnoйflow)
• 22.5йmA
Load
0йtoй700йΩ
Resolution
0.5йµA
Damping
Adjustable:й0.07йtoй999йs
Assignable measured
variables
• Volumeйflow
• Massйflow
• Flowйvelocity
• Electronicйtemperature
Pulse/frequency/switch output
Function
• Withйtheйorderйcodeйforй"Output;йInput",йoptionй
H
:йoutputй2йcanйbeйsetйasйaйpulse
orйfrequencyйoutput
• Withйtheйorderйcodeйforй"Output;йInput",йoptionй
I
:йoutputй2йandй3йcanйbeйsetйasйa
pulse,йfrequencyйorйswitchйoutput
Version
Passive,йopenйcollector
Maximum input values
• DCй30йV
• 250йmA
Voltage drop
Forй25йmA:й≤йDCй2йV
Pulse output
Pulse width
Adjustable:й0.05йtoй2
й
000йms
Maximum pulse rate
10
й
000йImpulse/s
Pulse value
Adjustable
Assignable measured
variables
• Volumeйflow
• Massйflow
Frequency output
Output frequency
Adjustable:й0йtoй12
й
500йHz
Damping
Adjustable:й0йtoй999йs
Pulse/pause ratio
1:1
Assignable measured
variables
• Volumeйflow
• Massйflow
• Flowйvelocity
• Electronicйtemperature
Switch output
Switching behavior
Binary,йconductiveйorйnon-conductive
Switching delay
Adjustable:й0йtoй100йs