Chart of a measured value trend
• x-axis:йdependingйonйtheйnumberйofйchannelsйselectedйdisplaysй250йtoй1000йmeasured
valuesйofйaйprocessйvariable.
• y-axis:йdisplaysйtheйapproximateйmeasuredйvalueйspanйandйconstantlyйadaptsйthisйtoйthe
ongoingйmeasurement.
Ifйtheйlengthйofйtheйloggingйintervalйorйtheйassignmentйofйtheйprocessйvariablesйtoйthe
channelsйisйchanged,йtheйcontentйofйtheйdataйloggingйisйdeleted.
Navigation
"Diagnostics"йmenuй йDataйlogging
"Data logging" submenu
Data logging
Assignйchannelй1
Assignйchannelй2
Assignйchannelй3
Assignйchannelй4
Loggingйinterval
Clearйloggingйdata
Parameter overview with brief description
Parameter
Description
Selection / User entry
Factory setting
Assignйchannelй1
Assignйprocessйvariableйtoйloggingйchannel.
• Off
• Volumeйflow
• Massйflow
• Flowйvelocity
• Electronicйtemperature
• Currentйoutputй1
Off
Assignйchannelй2
Assignйprocessйvariableйtoйloggingйchannel.
Picklistйсseeй
Assign channel 1
parameter)
Off
Assignйchannelй3
Assignйprocessйvariableйtoйloggingйchannel.
Picklistйсseeй
Assign channel 1
parameter)
Off
Assignйchannelй4
Assignйprocessйvariableйtoйloggingйchannel.
Picklistйсseeй
Assign channel 1
parameter)
Off
Loggingйinterval
Defineйtheйloggingйintervalйforйdataйlogging.
Thisйvalueйdefinesйtheйtimeйintervalйbetween
theйindividualйdataйpointsйinйtheйmemory.
1.0йtoй3
й
600.0йs
10.0йs
Clearйloggingйdata
Clearйtheйentireйloggingйdata.
• Cancel
• Clearйdata