Proline Promag 50H, 53H
42
Hauser
Flange DIN 11864-2
Sensor
Fits to
di
G
D
L
LK 1
LK 2
Aseptic flat flange, Form A
1.4404 / 316L
5*H**-4***********
DN
[mm]
Piping
DN 11850
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
A0005546
40
42 × 2
38
82
92
64
71.0
65
50
54 × 2
50
94
105
64
83.5
77
65
70 × 2
66
113
121
64
100.0
95
80
85 × 2
81
133
147
98
121.0
112
100
104 × 2
100
159
168
98
141.5
137
• – Fitting length for DN 40 to 65 = (2 × L) + 136 mm
– Fitting length for DN 80 to 100 = (2 × L) + 196 mm
• If pigs are used for cleaning, it is essential to take the inside diameters of
measuring tube and process connection (di) into account!
Coupling SMS 1145
Sensor
Fits to
SMS
1145
di
G
D
L
LK
Threaded adapter; 1.4404 / 316L
5*H**-5***********
DN
[mm]
Piping
OD
Dia-
meter
[mm]
[mm]
[mm]
[mm] [mm]
[mm]
A0005538
40
38.1 × 1.65
38.0
35.5
Rd 60 × 1/6"
92
63
71.0
50
50.8 × 1.65
51.0
48.5
Rd 70 × 1/6"
105
65
83.5
65
63.5 × 1.65
63.5
60.5
Rd 85 × 1/6"
121
70
100.0
80
76.2 × 1.65
76.0
72.0
Rd 98 × 1/6"
147
75
121.0
100
101.6 × 1.65
101.6
97.6
Rd 132 × 1/6"
168
70
141.5
• – Fitting length for DN 40 to 65 = (2 × L) + 136 mm
– Fitting length for DN 80 to 100 = (2 × L) + 196 mm
• If pigs are used for cleaning, it is essential to take the inside diameters of
measuring tube and process connection (di) into account!
Coupling ISO 2853
Sensor
Fits to
piping
ISO 2853
di
G
D
L
LK
Threaded adapter; 1.4404 / 316L
5*H**-6***********
DN
[mm]
ISO 2037 /
BS 4825-1
Diameter
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
A0005542
40
38.0 × 1.6
38.0
35.6
50.6
92
61.5
71.0
50
51.0 × 1.6
51.0
48.6
64.1
105
61.5
83.5
65
63.5 × 1.6
63.5
60.3
77.6
121
61.5
100.0
80
76.1 × 1.6
76.1
72.9
91.1
147
61.5
121.0
100
101.6 × 2.0
101.6
97.6
118.1
168
61.5
141.5
• – Fitting length for DN 40 to 65 = (2 × L) + 136 mm
– Fitting length for DN 80 to 100 = (2 × L) + 196 mm
• If pigs are used for cleaning, it is essential to take the inside diameters of
measuring tube and process connection (di) into account!
L
G
di
D
LK
1
LK
2
D
LK
di
G
L
G
di
D
LK
L