Proline Promag 50H, 53H
Hauser
47
Human interface
Display elements
• Liquid crystal display: backlit, two lines (Promag 50) or four lines (Promag 53) with 16 characters per line
• Custom configurations for presenting different measured-value and status variables
• Totalizer
– Promag 50: 2 totalizers
– Promag 53: 3 totalizers
Operating elements
Unified operation concept for both types of transmitter:
Promag 50:
• Local operation via three keys (
S
,
O
,
F
)
• Quick Setup menus for straightforward commissioning
Promag 53:
• Local operation via three keys (
S
,
O
,
F
)
• Application-specific Quick Setup menus for straightforward commissioning
Language groups
Language groups available for operation in different countries:
Promag 50, Promag 53:
• Western Europe and America (WEA):
English, German, Spanish, Italian, French, Dutch, Portuguese
• Eastern Europe and Scandinavia (EES):
English, Russian, Polish, Norwegian, Finnish, Swedish, Czech
• South and east Asia (SEA):
English, Japanese, Indonesian
Promag 53:
• China (CN):
English, Chinese
You can change the language group via the operating program "FieldCare".
Remote operation
• Promag 50: Remote control via HART, PROFIBUS DP/PA
• Promag 53: Remote control via HART, PROFIBUS DP/PA, MODBUS RS485, FOUNDATION Fieldbus
Certificates and approvals
CE mark
The measuring system is in conformity with the statutory requirements of the EC Directives.
Hauser confirms successful testing of the device by affixing to it the CE mark.
C-tick mark
The measuring system meets the EMC requirements of the "Australian Communications and Media Authority
(ACMA)".
Pressure measuring device
approval
The measuring devices can be ordered with or without PED (Pressure Equipment Directive). If a device with
PED is required, this must be ordered explicitly. For devices with nominal diameters less than or equal to
DN 25 (1"), this is neither possible nor necessary.
• With the identification PED/G1/III on the sensor nameplate, Hauser confirms conformity with the
"Basic safety requirements" of Appendix I of the Pressure Equipment Directive 97/23/EC.
• Devices with this identification (with PED) are suitable for the following types of fluid:
– Fluids of Group 1 and 2 with a steam pressure of greater or less than 0.5 bar (7.3 psi)
– Unstable gases
• Devices without this identification (without PED) are designed and manufactured according to good
engineering practice. They correspond to the requirements of Art. 3, Section 3 of the Pressure Equipment
Directive 97/23/EC. Their application is illustrated in Diagrams 6 to 9 in Appendix II of the Pressure
Equipment Directive 97/23/EC.
Ex approval
Information about currently available Ex versions (ATEX, FM, CSA etc.) can be supplied by your
Hauser Sales Center on request. All explosion protection data are given in a separate documentation
which is available upon request.