Liquiphant S FTL70, FTL71
17
Operating conditions
Installation
Installation instructions
Examples of mounting
Examples of mounting with regard to the viscosity
ν
of the liquid and the tendency to form buildup
Optimum mounting, without problem even with high viscosity:
With buildup on the tank walls:
Mounting positions with low viscosity (up to 2000 mm
2
/s):
Switch points
on the sensor depend on the mounting position, with reference to water,
Density 1 g/cm
3
, 23 °C, p
e
0 bar.
L00-FTL5xxxx-06-05-xx-xx-001
Mounting from above
Mounting from below
Mounting from the side
13
mm
4m
m
4m
m
Position the fork so that the narrow edge of the tines is vertical.
This ensures that the liquid can run off easily.
L00-FTL7xxxx-11-05-xx-xx-002
Vertical from above
Flush-mounted from the side
* Ensure that there is sufficient distance between the buildup expected on the tank wall and the fork.
L00-FTL7xxxx-11-05-xx-xx-003
Vertical from above
Protruding into the tank from the side
* Deburr the nozzle surfaces
*
*