Liquiphant S FTL70, FTL71
29
Certificates and approvals
Certificates
• See Liquiphant S FTL70 FTL71 ordering information
→
ä
31
• Leak-detection system in conjunction with WHG approval
Approval number: Z–65.40–446
(See also "Ordering information"
→
ä
31)
• TSE Certificate of Suitability
The following applies to wetted device components:
– They do not contain any materials derived from animals.
– No additives or operating materials derived from animals are used in production or processing.
!
Note!
Wetted device components are listed in the "Mechanical construction“ (
→
ä
22+) and "Ordering
information" (
→
ä
31) sections.
CRN approval
Versions with a CRN approval: 0F10904.5C (Canadian Registration Number) are marked with a "*" in ordering
information (
→
ä
31+) feature 20 "process connection".
Combinations
of housings and
electronic inserts
Please refer to the Safety Instructions on ATEX, NEPSI etc. for the permitted combinations of housing versions
and electronic inserts. A list of the available documents can be found on
→
ä
39+. The actual documents can
be found on the product pages at www.endress.com.
Abbreviations used:
Housing
Electronic inserts
F16 polyester housing
F17 aluminum housing (plug-in)
F13 aluminum housing (threaded)
T13 aluminum housing (separate connection
compartment)
F15 stainless steel housing (for hygiene applications)
F27 stainless steel housing (precision casting)
FEL50A Profibus PA
FEL51 SIL 2-wire 19-253VDC
FEL52 3-wire PNP
FEL54 relay DPDT 19-253VAC/19-55VDC
FEL55 8/16mA, 11-36VDC
FEL56 NAMUR (L-H signal)
FEL57 2-wire PFM
FEL58 NAMUR+ test keys (H-L signal)
A:
Non-hazardous area
F16, F17, F13, T13, F15, F27 FEL51/52/54
FEL50A/55/56/57/58
B:
ATEX/NEPSI II 3G EEx nC II T6, WHG
F16, F17, F13, T13, F15, F27 FEL54
C:
ATEX/NEPSI II 3G EEx nA II T6, WHG
F16, F17, F13, T13, F15, F27 FEL51/52
FEL50A/55/56/57/58
D:
Non-hazardous area, WHG
F16, F17, F13, T13, F15, F27 FEL51/52/54
FEL50A/55/56/57/58
E:
ATEX II 1/2G EEx de IIC T6, WHG/IEC
Zone 0/1
T13
FEL51/52/54
FEL50A/55/56/57/58
F:
ATEX II 1/2GD Ex ia IIC T6, WHG/IEC
F17, F13, T13, F15, F27
FEL50A/55/56/57/58
L:
ATEX II 1/2G EEx d IIC T6, WHG/IECE
Zone 0/1
F13, T13, F27
FEL51/52/54
FEL50A/55/56/57/58
M: NEPSI Ex ia IIC T6
F16, F17, F13, T13, F15, F27 FEL50A/55/56/57/58
N:
NEPSI Ex d IIC T6
F13, T13, F27
FEL51/52/54
FEL50A/55/56/57/58
P:
FM IS Cl.I, II ,III Div.1 Gr.A-G, Zone 0, 1, 2,
20, 21, 22
F16, F17, F13, T13, F15, F27
(with NPT cable entry)
FEL50A/55/56/57/58
Q:
FM XP Cl.I, II, III Div.1 Gr.A-G, Zone 1, 2,
21, 22
F13, T13, F27
FEL51/52/54
FEL50A/55/56/57/58
R:
FM NI Cl.I Div.2 Gr.A-D, Zone 2
F16, F17, F13, T13, F15, F27 FEL51/52/54
FEL50A/55/56/57/58
S:
CSA IS Cl I, II, III Div.1 Gr.A-G, Zone 0, 1, 2 F16, F17, F13, T13, F15, F27
(with NPT cable entry)
FEL50A/55/56/57/58
T:
CSA XP Cl I, II, III Div.1 Gr.A-G, Zone 1, 2
F13, T13, F27
FEL51/52/54
FEL50A/55/56/57/58
U:
CSA General Purpose
F16, F17, F13, T13, F15, F27 FEL51/52/54
FEL50A/55/56/57/58