Liquiphant S FTL70, FTL71
22
Mechanical construction
Design
Summary of all electrical and mechanical versions
Plug-in electronic inserts to mount in the housing
Housing
Temperature spacer
Process connections
L00-FTL5xxxx-03-05-xx-xx-000
FEL51:
FEL52:
FEL54:
FEL55:
FEL56:
FEL58:
FEL57:
FEL50A:
Two-wire AC connection
Three-wire DC connection PNP
Universal current connection, 2 relay outputs
Output 16/8 mA for separate switching unit
Output 0.6 to 1.0 / 2.2 to 2.8 mA for separate switching unit (NAMUR)
Output 2.2 to 3.5 / 0.6 to 1.0 mA for separate switching unit (NAMUR)
Output 150/50 Hz, PFM, for separate switching unit (Nivotester)
Digital communication PROFIBUS PA
L00-FTL5xxxx-03-05-xx-xx-001
L00-FTL5xxxx-03-05-xx-xx-002
L00-FTL5xxxx-03-05-xx-xx-003
L00-FTL5xxxx-03-05-xx-xx-004
F16
Polyester (PBT)
F15
Stainless steel (316L)
F13
Coated aluminum
(also for Ex d)
F17
Coated aluminum
F27
Stainless steel (316L),
(also for Ex d)
T13
Aluminum with separate
connection compartment (also
Ex de and Ex d), coated
Temperature spacer with welded gas-tight feed-through
(standard version)
Approx. 160 mm to 230 °C ("L")
Approx. 200 mm to 280 °C ("N")
L00-FTL7xxxx-03-05-xx-xx-002
L00-FTL5xxxx-03-05-xx-xx-006
L00-FTL5xxxx-03-05-xx-xx-007
L00-FTL5xxxx-03-05-xx-xx-009
G ¾, DIN ISO 228/I
R ¾, DIN 2999
NPT ¾, ANSI B 1.20.1
(AF 32)
G 1, DIN ISO 228/I
R 1, DIN 2999
NPT 1, ANSI B 1.20.1
(AF 41)
Flanges to DIN, ANSI, JIS
from DN 25 / 1"