Cerabar M, Deltabar M, Deltapilot M / 4...20 mA HART
Installation
Hauser
19
Flow measurement in steam
P01-PMD55xxx-11-xx-xx-xx-001
Measuring layout for flow measurement in steam
1
Condensate traps
2
Orifice plate or pitot tube
3
Shut-off valves
4
Deltabar M
5
Separator
6
Drain valves
7
Three-valve manifold
• Mount the Deltabar M below the measuring point.
• Mount the condensate traps at the same level as the tapping points and at the same distance to
the Deltabar M.
• Prior to commissioning, fill the impulse piping to the height of the condensate traps.
Flow measurement in liquids
P01-PMD55xxx-11-xx-xx-xx-002
Measuring layout for flow measurement in liquids
1
Orifice plate or pitot tube
2
Shut-off valves
3
Deltabar M
4
Separator
5
Drain valves
6
Three-valve manifold
• Mount the Deltabar M below the measuring point so that the impulse piping is always filled with
liquid and gas bubbles can run back into the process piping.
• When measuring in media with solid parts, such as dirty liquids, installing separators and drain
valves is useful for capturing and removing sediment.
➀
➁
➃
+
–
➂
➅
➄
➆
➂
➅
➄
+
–
➀
➂
➅
➁
➃
➄
➁
➃
➄