Trouble-shooting
CleanFit CPA 451
20
Hauser
7
Trouble-shooting
7.1
Replacing damaged parts
#
Warning!
Damage to the assembly which affects the pressure safety must
only
be repaired by
authorised technical personnel.
After every repair and maintenance activity, suitable measures must be taken to test
whether the assembly shows any signs of leaking. The assembly must then correspond
to the specifications stated in the technical data.
Replace all other damaged components immediately. To order accessories and spare
parts, please use the "Accessories" and "Spare parts" chapters or contact your E+H
Sales Center.
7.2
Replacing seals
•
Keep the sealing surfaces of the assembly free of dirt.
•
Remove deposits clinging to the assembly from time to time.
•
In the event of leakages, contact your E+H Sales Center.
#
Warning!
Risk of medium leaking out!
Seals must
only
be replaced by authorised technical personnel.
You can replace the following seals (Fig. 20):
•
O-ring Viton, in contact with the medium
•
O-rings Viton, not in contact with the medium
#
Warning!
The assembly has to be separated from the process connection to replace the seals.
For this purpose, the following conditions must be met:
•
The process must be switched off.
•
Piping or container must be empty.
C07-CXA451xx-00-07-07-xx-001.eps
Fig. 20:
Seals
1
O-ring Viton, in contact with the medium
2
O-rings Viton, not in contact with the medium
1
2
Summary of Contents for CleanFit CPA 451