Outdoor Patio Heater Model No. GWT801B
Contact 1.800.762.1142 for assistance. Do not return to place of purchase.
page no.
7
Note
: The burner may be noisy when initially turned on. To eliminate excessive noise from the
burner, turn the control knob to the “LOW” position. Then, turn the knob to the level of heat
desired.
When heater is “ON”:
Emitter screen will become bright red due to intense
heat. The color is more visible at night.
Burner will display tongues of blue flame. These flames
should not be yellow or produce thick black smoke,
indicating an obstruction of airflow through the burners.
If yellow flame is detected, turn off heater and gas
supply and consult “Troubleshooting”.
Visually check burner flames at each use and make
sure flame height matches illustration.
Re-lighting
Note: For your safety, control knob cannot be turned on
without first depressing control knob in off position and
then rotating to on.
1. Turn gas control knob to off.
2. Wait at least 5 minutes to let gas dissipate before
attempting to relight burner.
3. Repeat the “Lighting” steps 2 and 3.
Turning Off
1. Rotate gas control knob to off position. Normally, burner will make a slight popping sound
when extinguished.
2. Turn off gas at LP gas tank, or unscrew 14.1 oz or 16.4 oz LP gas tank.
3. Remove access panel.
4. Unscrew gas line from regulator.
5. Close access panel.
Note: After use, some discoloration of the emitter screen is normal.
Cleaning and Care
Notices
1. Abrasive cleaners will damage this product.
2. Never use oven cleaner to clean any part of heater.
3. Do not clean any heater part in a self cleaning oven. The extreme heat will damage
the finish.
4. More frequent cleaning may be required as necessary. It is imperative that control
compartment, burners and circulating air passageways of the heater be kept clean.
5. Spiders and insects can create a dangerous condition that may damage heater or
make it unsafe. Keep burner area clean of all spiders, webs, or insects. Clean burner
holes by using a heavy-duty pipe cleaner. Compressed air may help clear away
smaller particles.
6. Inspect heater before each use.
7. Have heater inspected annually and repairs should be made by a qualified service
person.
8. Check heater immediately if any of the following conditions exist:
a. The smell of gas in conjunction with extreme yellow tipping of burner flames.
b. Heater does not reach proper temperature.
Note: At temperatures less than 40ºF, heat output will be reduced.
c. Heater’s glow is excessively uneven
d. Burner makes popping noises during use.
Note: A slight pop is normal when burner is extinguished.
9. Carbon deposits may create a fire hazard. Keep dome and emitter clean at all times.
10. Do not clean heater with combustible or corrosive cleaners. Use warm, soapy water.
11. Do not paint engine, engine access panel or dome.
12. This heater should be thoroughly cleaned on a regular basis.
13. After a period of storage and/or non use, check for leaks, burner obstructions and
inspect for any abrasion, wear, cuts to the hose.
Operating Instructions
Inspect the visible portion of the hose before each use of the appliance. Inspect the entire hose
assembly at least annually.
Checking for Leaks
Burner Connections
Make sure the regulator valve and hose connections
are securely fastened to the burner and the tank.
If your unit was assembled for you, visually check
the connection between the burner pipe and orifice.
Make sure the burner pipe fits over the orifice.
WARNING: Failure to inspect this
connection or follow these instructions
could cause a fire or an explosion which
can cause death, serious bodily injury, or
damage to property.
Please refer to diagram for proper installation.
If the burner pipe does not rest flush to the orifice,
please contact 1.800.762.1142 for assistance.
Tank/Gas Line Connection
Make 2-3 oz. of leak solution by mixing one part liquid
dishwashing soap with three parts water.
Make sure control knobs are off.
Turn LP gas tank ON at valve.
Spoon leak check solution at all “x” and arrow locations.
If any bubbles appear turn LP gas tank “OFF”, reconnect and re-test. If you continue to see
bubbles after several attempts, disconnect LP gas source and contact 1.800.762.1142 for
assistance.
If no bubbles appear after one minute turn tank “OFF”, wipe away solution and proceed.
Before Turning Gas Supply ON
Your heater was designed and approved for OUTDOOR USE ONLY. DO NOT use it inside a
building, garage, or any other enclosed area.
Make sure surrounding areas are free of combustible materials, gasoline, and other flammable
vapors or liquids.
Ensure that there is no obstruction to air ventilation.
Be sure all gas connections are tight and there are no leaks.
Be sure the access panel is clear of debris.
Be sure any component removed during assembly or servicing is replaced and fastened prior
to starting.
Before Lighting
Heater should be thoroughly inspected before each use, and by a qualified service person at
least annually.
If relighting a hot heater, always wait at least 5 minutes for gas to dissipate.
Lighting
1. Turn control knob to “OFF” position.
2. Turn on gas at LP gas tank.
3. Push in control knob and rotate to “ON” position. This will
activate the built-in ignitor and light the burner. If necessary,
keep depressing and rotating knob until burner lights.
4. Once burner is lit, hold control knob in for at least 30 seconds
and release.
5. If burner does not stay lit, turn to “OFF” position and wait 5
minutes and repeat steps 2
and 3.
6. If ignitor does not light burner, use a lit match positioned against
the bottom of emitter screen at burner location, and repeat steps
2 and 3.
7. Once burner is lit, rotate knob to desired heating level.
If you experience any ignition problem, turn off the heater and gas
supply, and consult “Troubleshooting”.
Caution: Avoid inhaling fumes emitted from the heater’s first use. Smoke
and odor from the burning of oils used in manufacturing will appear. Both
smoke and odor will dissipate after approximately 30 minutes. The heater
should NOT produce thick black smoke.
Cleaning Surfaces
1. Wipe surfaces clean with mild dishwashing detergent or baking soda.
2. For stubborn surfaces use a citrus based degreaser and a nylon scrubbing brush.
3. Rinse clean with water.
Note: While cleaning your unit, be sure to keep the area around the burner and pilot assembly
dry at all times. Do not submerge the control valve assembly. If the gas control is submerged
in water, do NOT use it. It must be replaced.
Maintenance
To enjoy years of outstanding performance from your heater, make sure you perform the
following maintenance activities on a regular basis:
1. Keep exterior surfaces clean.
2. Air flow must be unobstructed. Keep controls, burner, and circulating air passageways clean.
Signs of possible blockage include:
Gas odor with extreme yellow tipping of flame.
Heater does NOT reach the desired temperature.
Heater glow is excessively uneven.
Heater makes popping noises.
Note: In a salt-air environment (such as near an ocean), corrosion occurs more quickly than
normal. Frequently check for corroded areas and repair them promptly.
TIP:
Use high-quality automobile wax to help maintain the appearance of your heater. Apply to
exterior surfaces from the pole down. Do not apply to emitter screen or domes.
Storage
Between uses:
1. Turn Control Knob OFF.
2. Disconnect LP source and move to a secure, well-ventilated location outdoors.
3. Store heater upright in an area sheltered from direct contact with inclement weather (such
as rain, sleet, hail, snow, dust and debris).
4. If desired, cover heater to protect exterior surfaces and to help prevent build up in air
passages.
Note: Wait until heater is cool before covering.
During periods of extended inactivity or when transporting:
1. Turn Control Knob OFF.
2. Disconnect LP source and move to a secure, well-ventilated location outdoors.
3. Store heater upright in an area sheltered from direct contact with inclement weather (such
as rain, sleet, hail, snow, dust and debris).
4. If desired, cover heater to protect exterior surfaces and to help prevent build up in air
passages.
5. Never leave LP canister exposed to direct sunlight or excessive heat.
Note: Wait until heater is cool before covering.
Product Registration
For faster warranty service, please register your product immediately at www.bluerhino.com or
call 1.800.762.1142.
Cleaning and Care (continued)