1. Setting up

CERTIFICATE OF CE-CONFORMITY 

ANALYTICAL SIEVE SHAKER

Air Sizer 200

Certificate of CE-Conformity according to:

EC Mechanical Engineering Directive 2006/42/EC

Applied harmonized standards, in particular: 
EN ISO 12100 

Security of machines

EC Directive Electromagnetic Compatibility 2004/108/EC

Applied standards, in particular:

EN55011:2009+A1:2010, Group 1, Class B        Radio disturbance characteristics –  

Limits and methods of measurement

EN 61000-3-2:2006+A1:2009+A2:2009
EN 61000-3-3:2008
EN61326-1:2006

Additional applied standards, in particular

EN 61010 Safety prescriptions concerning measuring, operating, controlling and laboratory equipment

Authorised for the compilation of technical documents:

Endecotts Ltd (technical documentation)

The following records are held by Endecotts Ltd in the form of Technical Documentation:

Detailed records of engineering development, construction plans, study (analysis) of the measures required 
for conformity assurance, analysis of the residual risks involved and operating instructions in due form 
according to the approved regulations for preparation of user information data.

The CE-conformity of the Endecotts Analytical Sieve Shaker Type Air Sizer 200 is assured herewith.

In case of a modification to the machine not previously agreed with us as well as the use of not licensed 
spare parts and accessories this certificate will lose its validity.

Endecotts Ltd

London, July

QAQC LAB 589 Rappahannock Drive White Stone Va 22578 TEL (804) 318-3686

Summary of Contents for Air Sizer 200

Page 1: ...1 Technical specifications Copyright by Endecotts Ltd 45 1 Technical specifications 6 Operating instructions Air Sizer 200 QAQC LAB 589 Rappahannock Drive White Stone Va 22578 TEL 804 318 3686...

Page 2: ...the sieve mesh constantly The Air Sizer 200 is specially designed for the dry sieving and the particle size determination of fine grained dry pourable and dispersed bulk materials The sieve holder is...

Page 3: ...actions 1 Amplitude N A Speed 5 to 55 rpm Time display digital 00 10 99 50 min Suitable for dry sieving yes Suitable for wet sieving no Sieve diameter 203 mm 8 premium air jet sieves Clamping device N...

Page 4: ...and the controls and indicators before operating this machine PLEXIGLASS LID FOR AIR JET SIEVING TEST SIEVE AIR OUTLET CHANNEL MAINS SWITCH CONTROL PANEL COVER BASE NOZZLE COMPARTMENT MAINS POWER CONN...

Page 5: ...icate START button ON 4 Start the machine by pressing the START button 5 7 and button reduces increases the sieving time 00 10 99 50 min 6 Stop the machine by pressing the STOP button 8 9 and button r...

Page 6: ...n change to an unknown degree Atmospheric humidity Maximum relative humidity 80 at temperatures up to 31 C with linear reduction down to 50 relative humidity at 40 C At high atmospheric humidity the e...

Page 7: ...perated Take Care the Air sizer 200 weighs 14 kg x 1 off Set up Instructions x 1 off Mains Cable x 1 off Air Sizer fitted x 1 off Plexiglas lid x Soft Faced Mallet x Test Sieving Manual Position the A...

Page 8: ...ith a diameter of 203mm 8 inches The range of mesh fineness extends from 10 m to approx 4mm x Place the sieve in the nozzle compartment x Fit the Plexiglas lid provided NOTE The Air Sizer 200 cannot b...

Page 9: ...ot be used as a production machine nor is it intended for continuous operation Note Defects in components due to liquids Penetration of liquids inside the housing x Components are damaged and the corr...

Page 10: ...er to life through electric shock x An electric shock can lead to burns and to cardiac arrhythmias or to respiratory arrest and cardiac arrest x The device may only be operated with plugs that have a...

Page 11: ...mbar sensor could be destroyed The air jet can be changed by turning the manual air jet setting 1 Air entry opening closed maximum air jet 2 Air entry opening open minimum air jet The difference in ai...

Page 12: ...on the sample property flow speed and air humidity Cleaning and service WARNING Risk of a fatal electric shock An electric shock can cause injuries in the form of burns and cardiac arrhythmia respirat...

Page 13: ...This device is essentially maintenance free if cleaned regularly E11 MOTOR FAULTY BLOCKED Service required E83 VACUUM TOO LOW Check whether the suction apparatus is connected the suction apparatus is...

Page 14: ...laboratory equipment Authorised for the compilation of technical documents Endecotts Ltd technical documentation The following records are held by Endecotts Ltd in the form of Technical Documentation...