13
MEASUREMENT PROCEDURES
Test the SOC (State of Charge) and SOH (State of Health) of the battery.
①
Connect Black clip and Red clip to battery
minus
○
−
terminal and plus
○
+
terminal
respectively.
When you cannot connect battery clips to
battery terminal directly, connect them to
the point from the terminals well as close
as possible.
※
In this case a CCA may be measured
lower than a real value.
Red
Black
Battery
●
Check the battery visually before connecting Battery Clips to the battery terminals.
●
Replace the Battery Terminals if there is corrosion or crack occurs on the
Terminals.
●
Connect the Battery Clips to the Battery Terminals tightly without loosening.
●
Clean up the Battery Terminals and Battery Clips if there is greasy dirt.
●
Replace the battery which is damaged, deformed of the Battery and broken the
Battery Terminals.
●
Add the purified water and do auxiliary charge if the level of battery fluid
decreases near to the border of LOWER.
●
Replace the battery that the level of battery fluid is lower than the border of
LOWER with discolored battery fluid.
Test Preparation
MENU
BAT TERY
CHECKER
SK-8535
CHARGE
BAD
GOOD
MAX 32V
●
Make sure to connect the Battery Clips to Battery Terminals to
obtain the accurate measurement.
●
Clean up the Battery Terminals and the Battery Clips before testing
to obtain the accurate measurement.
CAUTION