background image

17

 

 

 

 

 

 

MT54 to PC 

Wiring 

Diagram 

 

                 

 

 

  2.3.3 USB Connection 

The USB port on the back of the case is the USB Slave device used to connect with a PC for con- 
figuration  downloading  and  HMI  setting.  It  cannot  be  used  to  connect  with  peripheral  equipment 
such as the USB printer.   

Connection 

USB Slave port can be connected with a PC through a general USB cable.   

Port Function 

The port is only used to download user configuration program to the HMI and 

to set HMI system parameters. 

Port Diagram 

 

 

2.3.4 Ethernet Connection 

The Ethernet interface on the back of the product enclosure is a 10M/100M adaptive Ethernet port. 

 

Connection 

This port is connected with the HUB or Switch through a standard Ethernet cable 
(RJ-45 straight-through cable) and then connected to a LAN. It can also be directly 
connected  with  the  Ethernet  port  of  a  PC  through  a  dual  system  interconnection 
cable (RJ-45 crossover cable). 

Port 

Function 

The port can be used for upload/download of HMI configuration, setting of system 
parameters and online simulations of configurations. It can connect multiple HMIs 
via  the  Ethernet  to  form  an  HMI  network.  Furthermore,  it  can  implement 
communications  between  HMI  and  PLC  via  the  Ethernet,  as  well  as 
communications with a PC via the Ethernet port.   

Port 

Diagram 

 

 

Summary of Contents for EOP5-057 Series

Page 1: ...ndedir Uygun bi imde NEMA 4 paneline kuruldu u zaman tehlike olu turmayacakt r Bu da y kay p temizleme esnas nda s v lar n panel i erisine girmeyece i anlam na gelmektedir Elektriksel Ko ullar EOP5 05...

Page 2: ...artnamesine bak n z Operat r panelini patlama tehlikesi olan yan c gazlar n bulundu u buharl veya tozlu ortamlarda al t rmay n z Operat r panel cihazlar h zl s cakl k de i iminin veya y ksek nemin old...

Page 3: ...ve m mk n oldu unca kesit alan b y k olmal d r iletkenler maksimum k sa devre ak mlar n ta ma kapasitesine sahip olmal d r Topraklama hatt iletkenleri toprak noktalar na ba lanmal d r Bu hi bir topra...

Page 4: ...t elemanlar gibi ba lanmas n sa layan ba lant noktalar d r 2 3 1 Harici Cihazlar ile Ba lant Kablo Gereksinimi Farkl harici cihazlar i in farkl kablolara ihtiya duyulur nlem Uyar Cihaz enerjili iken k...

Page 5: ...o PLC RS 232 1 Rx A RS 485 Rx RS485A 2 RxD_PLC RS 232 Rx 3 TxD_PLC RS 232 Tx 4 Tx RS 485 Tx 5 GND Toprak 6 Rx B RS 485 Rx RS485B 7 CTS_PLC Veri giri i i in s f rla 8 RTS_PLC Veri k i in haz r 9 Tx RS...

Page 6: ...2 3 4 Eternet ile Ba lant Kurulmas Cihaz n arkas ndaki eternet ara y z 10M 100M adaptif Eternet porttur Ba lant Bu port standart eternet kablosu RJ 45 d z kablo ile HUB ya da anahtara sonra da LAN a...

Page 7: ...opsiyoneldir 2 sinyale sadece veri yolu kablo portu taraf nda ihtiya duyulur 2 3 6 CANbus Ara Y z Ba lant Port di er cihazlara zel kablo zerinden ba lan r Port Fonksiyonu EOP5 057 serisi operat r pane...

Page 8: ...onksiyonu Bu ara y z USB giri i Mouse ve yaz c ile ba lan r U disk kullan c n n uploading downloading konfig rasyonu ve veri saklama i in kullan l r Port emas 2 3 9 Audio Ara Y z Ba lant Standart 3 5m...

Page 9: ...enileme ve temel parametre ayar modu Bu mod uzman kullan c n n sistemi yenileme i lemi s ras nda kulland moddur E er bu konuda bilginiz yok ise teknik destekten bilgi edininiz Uygulama evrim i i al ma...

Page 10: ...RS232 RS485 2 RS485 4 COM2 RS232 USB Host Mouse yaz c klavye vb ba lanabilir Haberle me Yok PROFIBUS DP CANOPEN MPI Elektriksel zellikler G t ketimi 7 2 W al ma gerilimi 24V DC Giri aral 21V DC 28V DC...

Page 11: ...11 4 0 EOP5 057 Ebatlar Birim mm in nden G r n Yandan G r n stten G r n Arkadan G r n Yuva Kesiti Boyutu...

Page 12: ...panel the NEMA 4 rating of the panel will not be compromised It means that fluids will not enter the panel during wash downs Electrical environment EOP5 057 series has been tested to conform to Europe...

Page 13: ...ollowed See Hardware Specifications Do not operate the unit in areas subject to explosion hazards flammable gases vapors or dusts The unit should not be installed where fast temperature variation or h...

Page 14: ...return point to the star earth point ground conductors should be as short and as large in cross sectional area as possible the conductors should be able to carry the maximum short circuit current Gro...

Page 15: ...ttings The ports as you look at the back of the case are the ports for connecting to a Printer PC a PLC or some other peripherals such as Controller Connectors 2 3 1 Connection with External Devices C...

Page 16: ...1 Rx A RS 485 Rx RS485A 2 RxD_PLC RS 232 Rx 3 TxD_PLC RS 232 Tx 4 Tx RS 485 Tx 5 GND Signal ground 6 Rx B RS 485 Rx RS485B 7 CTS_PLC Clear to send input 8 RTS_PLC Ready to send output 9 Tx RS 485 Tx...

Page 17: ...ce on the back of the product enclosure is a 10M 100M adaptive Ethernet port Connection This port is connected with the HUB or Switch through a standard Ethernet cable RJ 45 straight through cable and...

Page 18: ...Note 1 s signal is optional 2 s signal is only needed at the site of bus cable port 2 3 6 CANbus Interface Connection The port can be connected with other equipments via a dedicated cable Port Functio...

Page 19: ...s interface can be connected with USB keyboard mouse and printers and the U disk can be used for user s configuration uploading downloading as well as data storage Port Diagram 2 3 9 Audio Interface C...

Page 20: ...ate and Basic Parameter Setting Mode This mode is for senior user to update the system if you are stranger please consult supporter Application Online Operation Mode This is the normal working mode of...

Page 21: ...B port Communication extending No support PROFIBUS DP expansion board supported CANOPEN expansion board supported MPI expansion board supported Electrical specification Rated power 7 2 W Rated voltage...

Page 22: ...22 4 0 Dimensional Drawing of EOP5 057 Unit mm inch Front View Side View Top View Rear View Cutout Size...