Independent alarm
Deviation alarm
PARAMETER LIST
I.typ
0-10
Initial Value
CONFIGURATION PARAMETERS
Input type selection. (
0-20
mA,
4-20
0-1 0-10
)
mA,
V,
V
d5p.C
Prc5
Indicator configuration. (
prc5 :
Process value,
Pr.Un :
4 Seconds process value, 2 Seconds
Unit
value.)
ratE
5lo.1
Hold
nonE
Indicator holding parameter. (
nonE
: instant measurement value,
lo. :
minimum value,
HI :
maximum value is displayed.)
Unit
nonE
Measurement value. (Desired measurement value for unit selection).
Cal.t
5.Inp
Calibration type. (
5.Inp
: Standard input type,
U.Inp
: User defined input type selection ).
d.Pnt
Decimal point selection. ( Adjustable between the 1th. and 3rd digits ).
L.5CL
Lower scale value. ( Adjustable between
-1999
and
H.5CL
value ).
H.5CL
1
Upper scale value. ( Adjustable between
L.5CL
and
4000
value ).
OUTPUT CONTROL PARAMETERS
O.HY5
Output hysteresis value. ( Adjustable between
1
and
200
).
O.5ta
Output status. (
Off
: Output not active,
Lo:
Becomes active below the setpoint output value,
H1:
Becomes active above the setpoint output value).
ALARM CONTROL PARAMETERS
a.HY5
Alarm hysteresis value. (
1
and
200
).
Adjustable between
a.5ta
Alarm condition. (
OFF:
Alarm not active. For independent or deviation alarm,
H1:
Alarm is active
above the set value. For band alarm,
BI.HI
: Activated in "in-band",
Bo.HI
: Activated in "out-band".)
Lo:
Alarm is active below the set value,
a.typ
Alarm type. (
IndE :
Independent alarm,
dE
: Deviation alarm,
band
: Band alarm)
RS485 MODBUS COMMUNICATION PARAMETERS
adr5
Slave device address. ( Adjustable between
1
and
247
)
baUd
Baudrate. (Can be adjusted as ;
Off
,
1200
,
2400
,
4800
,
9600
,
19200
kbps
)
9600
0
0
2000
2
oFF
2
indE
oFF
O.5Et
Output set value. ( Adjustable between
L.5CL
and
H.5CL
).
2000
a.5Et
2000
Alarm set value. (
L.5CL
and
H.5CL
).
Adjustable between
O.Pon
Required relay-on delay time in order to set output to active state after power-up. ( Adjustable between 0 and 99 minutes ).
01:00
O.ton
Output relay-on delay time. ( Adjustable between 0 and 99 minutes ).
01:00
O.toF
Output relay-off delay time. Adjustable between 0 and 99 minutes ).
(
01:00
A.Pon
Required relay-on delay time in order to set alarm output to active state after power-up. ( Adjustable between 0 and 99 minutes ).
01:00
A.ton
Alarm output relay-on delay time. ( Adjustable between 0 and 99 minutes ).
01:00
A.toF
01:00
Measurement ranges.
Fa5t
: Average of 1 measurement value is gathered in 200msec.
5lo.1
: Average of 4 measurement value is gathered in 200msec.
5lo2
: Average of 8 measurement value is gathered in 200msec.
5lo3
: Average of 16 measurement value is gathered in 200msec.
Initial Value
Initial Value
Initial Value
Alarm output relay-off delay time. Adjustable between 0 and 99 minutes ).
(
A.tyP.
=
indE
A.5Et
OFF
OFF
ON
ON
A.5tA.
=
Hi
A.5tA.
=
Lo
OFF
ON
O.5tA.
=
Hi
O.5tA.
=
Lo
O.5Et
OFF
ON
O.Hy5
O.5Et
O.Hy5
A.Hy5
A.5Et
O.5Et
:Output set value
A.Hy5
A.Hy5
A.5Et
:Alarm set value
Band alarm
A.tyP.
=
bAnd
O.5Et
OFF
OFF
ON
ON
A.Hy5
A.Hy5
A.5tA.
=
Bo.Hi.
A.5tA.
=
Bi.Hi.
O.5Et + A.5Et
O.5Et
-
A.5Et
O.5Et + A.5Et
O.5Et
-
A.5Et
A.Hy5
A.tyP.
=
dE.
A.5tA.
=
Hi
A.5tA.
=
Lo
O.5Et + A.5Et
OFF
OFF
ON
ON
A.Hy5
A.Hy5
O.5Et + A.5Et
O.5Et
ALARM CONDITIONS
OUTPUT CONDITION