ENVIRONMENTAL CONDITIONS

 Height

 Max. 2000m

 Ambient/storage temperature

 Relative humidity

0 ... +50°C/-25 ... 70°C (without icing)

Protection class

According to EN60529;      Front panel : IP65
                                           Rear Panel : IP20
                                               

 Do not use the device in locations subject to corrosive and flammable gasses.

 Supply voltage
 Power consumption

Max. 5VA
2.5mm² screw-terminal connections

   ±1% 
   4 digits, 12.5mm, 7 segment  LED

 Connection
 Scale

 Sensitivity
 Accuracy
 Time accuracy

 Display
 EMC
 Safety requirements 

 EN 61326-1: 2013 
 EN 61010-1: 2010 (Pollution degree 2, overvoltage category II)

ELECTRICAL CHARACTERISTICS

-60.0 ... +150.0°C (-76.0 ... +302.0°F)

0.1°C (Can be selected as 0.1

ºC 

or

 1ºC

.) 

±1°C  

CONTROL

 Control type

 Single set-point control
 On-Off control

 Control algorithm
 Hysteresis

 Adjustable between 1 ... 20.0°C. 

OUTPUTS

HOUSING

 Housing type

 Suitable for flush -panel mounting

 Dimensions  

 W77xH35xD61mm 

 Weight 

 Approx. 190g (After packing)  

 Enclosure material

 Self extinguishing plastics.

 While cleaning the device, solvents (thinner, benzine, acid etc.) or corrosive materials must not be used.

Relative humidity 80% for temperatures up to 31°C decreasing linearly to 50% relative humidity at 40°C.

  Fan relay output

For EDT2423A-X-R ; Relay : NO+NC 250V AC, 8A  ,
                                              1/2hp, 0.37kW 240V AC         

                                                     
                                          

Defrosting relay output 

Compressor relay
output

Life expectancy

For EDT2423A-X-R; Without load 30.000.000 switching;
                                 250V AC, 8A (resistive load) 100.000 switching.

For EDT2423A-X-R ; Relay : NO 250V AC, 8A , 
                                              1/2hp, 0.37kW 240V AC  
                                                       
                                             

Device must be protected against inadmissible  humidity, vibrations, severe soiling and make sure that the operation 
temperature is not exceeded. The cables should not be close  to the power cables or components. 

Holding screw
0.4-0.5Nm.

 

Equipment is protected throughout by 

DOUBLE INSULATION

SUPPLY:

NOTE:

184-253V AC 
50/60Hz 4VA

Line

Neutral

230V AC
Supply

 

Switch

Note: 

Cable size: 1,5mm²

Fuse 

F 100 mA 

250V AC

Fuse should 
be connected

1)

 Mains supply cords shall meet the requirements of  

    IEC 60227 or IEC 60245. 

2)

 In accordance with the safety regulations, the power 

    supply switch shall bring the identification of the 
    relevant instrument and it should be easily 
    accessible by the operator.

1

2

DIMENSIONS

 Note:  

space at the back side of

difficult to remove it from

1)

 Panel thickness should

be maximum 7mm.

2)

 If there is no 60mm free

the device,it would be 

the panel. 

Flush mounting

clamp

For removing mounting clamps:  

out the clamp in direction 

2

 .

 

Push the flush-mounting 

clamp in direction 

1

 as shown 

in the figure below.Then,pull

71,5mm

28,5mm

Panel cut-out

  61mm                    5mm

  Flush mounting
         clamp

Panel

Rubber
 packing

2

Depth

77mm

35mm

1

      EDT2423A-E-05-201016

ENDA

 

INDUSTRIAL ELECTRONICS

SN: XXXXXXXXX

ENDAKEY

230V 

AC +10% -20%

50/60Hz  5V

A

8

68

04

07

70

24

28

1

2

3

4

5

6

7

8

EDT2412-230-R

DIGITAL

 DEFROST 

THERMOSTA

T

DEFROST

250V 

AC 8A

(LIGHT)

COMP

250V 

AC 8A

RESISTIVE

LOAD

9

10

     

NTC

 

         

GND

11

12

D.INP1

Made in Turkey

Please read this document carefully before using this product. The guarantee will be invalidated if the device is 
damaged by not following instructions detailed in the manual. The company shall not be responsible for any 
damage or losses however caused, which may be experienced as a result of the installation or use of this 
product.

Order Code : EDT2423A -           -    -             

1

2

3

1 - Supply Voltage

     230........230V AC
     110........110V AC
     24  ........24V AC/DC   
     12  ........12V AC/DC

     SM.........10-30V DC/8-24V AC
     24V........12V / 24V DC  
     

3 - ModBus Selection

   

                                         

     

RS.........ModBus (Optional)

     Blank.....N/A
     

(Must be specified at order)

                                                     
                     
                                   
                  

2 -  Contact Current Selection

      R.......8A Contact Output
      P.......16A Contact Output
     

SİSEL MÜHENDİSLİK ELEKTRONİK SAN. VE TİC. A.Ş.

Şerifali Mah. Barbaros Cad. No:18 Y.Dudullu  34775
ÜMRANİYE/İSTANBUL-TURKEY
Tel : +90 216 499 46 64 Pbx.    Fax : +90 216 365 74 01
url : www.enda.com.tr

 35x77mm size.

 On-Off control.

 Three relay outputs for cooling, defrost and fan control.

 Two NTC probe input for cooling and defrost control.

 Offset point can be entered for NTC input.

 Compressor protection parameters can be entered.

 In case of probe failure, compressor operation can be 

   set to ON, OFF or periodic.

 Selectable smart defrost feature.

 Defrost initiated by evaporator temperature, time 

   dependent or manual operation.

 Lower and upper limits of the set point can be set.

 Defrost time and interval can be adjusted.

 Lower and upper alarm limit can be set to dependent 

    on set point.

 Temperature can be displayed in ° C or ° F.

 Digital input.

 Transfer device parameter settings with ENDA key

    - no power-up required.

 RS485 communication features with Modbus RTU 

   protocol (optional).

 CE marked according to European standards.

D.INP

14 15 16

ENDA

 

INDUSTRIAL ELECTRONICS

SN: XXXXXXXXX

EDT2423A-230-P-RS
DIGITAL DEFROST 
THERMOSTAT

ENDAKEY

11 12 13

        

COM

           

B

        

A

8 6 8 0 4 0 7 7 2 5 4 1 0

     

DEF

.NTC

 

1

2

3

4

5

6

7

230V AC +10% -20%
50/60Hz  5VA

DEFROST 250V 8A~

F

AN

250V 5A~

8

9

10

     THER.NTC

 

     GND

Made in Turkey

COMP 250V 16A~

     

DEF

.NTC

 

1

2

3

4

5

6

7

EDT2423A-230-R
DIGITAL DEFROST 
THERMOSTAT

230V AC +10% -20%
50/60Hz  5VA

DEFROST 250V 8A~

F

AN

250V 8A~

8

9

10

     THER.NTC

 

     GND

11 12

    D.INP

ENDA

 

INDUSTRIAL ELECTRONICS

SN: XXXXXXXXX

ENDAKEY

8 6 8 0 4 0 7 7 0 2 5 4 1

Made in Turkey

COMP 250V 8A~

For EDT2423A-X-R ; Relay : NO 250V AC, 8A , 
                                              1/2hp, 0.37kW 240V AC  

                                                       
                                             

SET

SET

 EDT2423A

ENDA

°F

°C

SET

SET

 EDT2423A

ENDA

°F

°C

For EDT2423A-X-R ; Relay : NO 250V AC, 16A , 
                                              1/2hp, 0.37kW 240V AC  
                                                       
                                             

For EDT2423A-X-R ; Relay : NO 250V AC,5A , 
                                              1/2hp, 0.37kW 240V AC  

                                                       
                                             

  230V AC 110V AC +%10 -%20, 50/60Hz ; 12V AC/DC 

± %

10 veya 24V AC/DC  

±%

10 veya 

10-30V DC / 8-24V AC ±10% SMPS

  

Summary of Contents for EDT2423A

Page 1: ...ng clamp For removing mounting clamps out the clamp in direction 2 Push the flush mounting clamp in direction 1 as shown in the figure below Then pull 71 5mm 28 5mm Panel cut out 61mm 5mm Flush mounting clamp Panel Rubber packing 2 Depth 77mm 35mm 1 EDT2423A E 05 201016 ENDA INDUSTRIAL ELECTRONICS SN XXXXXXXXX ENDAKEY 230V AC 10 20 50 60Hz 5VA 8 6 8 0 4 0 7 7 0 2 4 2 8 1 2 3 4 5 6 7 8 EDT2412 230 ...

Page 2: ... the user menu is entered afterwards first parameter s name is displayed in the user menu SET While a parameter was selected by pressing to key parameter s value is displayed the displayed this parameter can be changed with keys When the parameter name is shown no action is done after 3 seconds or to the key is pressing again to return to the parameter s name When the parameter name is shown keys ...

Page 3: ...s on 2 0 10 hr min ENDAKEY PARAMETER TRANSFER NOTE 1 No power up required for transfering the parameter by using ENDAKEY For long battery life ENDAKEY must be disconnected from device after the transferring process NOTE 2 Please specify at order ENDAKEY if required d 5mt Smart Defrost selection no Defrost counter between 2 defrost duration decrease irrespective of d int status of the compressor YE...

Page 4: ...0x0011 0x0012 0x0013 0x0015 word word word word word word word word word word word word word word word word word word word word word 1 1 HOLDING REGISTERS Input Register Addresses Decimal Hex 1 2 INPUT REGISTERS 0000d 0x0000 word Discrate Inputs Addresses Decimal Hex 1 3 DISCRATE INPUTS 0000d 0x0000 bit word 0x0014 0020d 0001d 0x0001 bit ENDA EDT2423A DIGITAL THERMOSTAT MODBUS PROTOCOL ADDRESS MAP...

Reviews: