Mar/07
MN
9
11.
When asked
Are you sure to exit(Y/N)?
, press
Y
to exit and
reboot.
CONCATENATION (JBOD)
This RAID array allows you to use one or two hard drives to a
JBOD(Just a Bunch Of Disks) array. Although JBOD doesn’t offer
other RAID functionality, it makes the hard disks appear to be a single
one by combining the drives into one larger logical one without any
capacity loss.
Rebuilding a Failed Mirror Set
When a failure to one member occurs, you will be notified by the
RAID BIOS during boot. The steps below will guide you in rebuilding
a failed mirror set.
1.
Replace he failed drive(s) with one of equal or greater capacity,
then start the computer.
2.
During boot press
Ctrl+S
or
F4
to enter the RAID BIOS.
3.
Select
Create RAID Set
press
Enter
.
4.
Select
SPARE DRIVE
, then press
Enter
.
5.
Select the single hard drive then press
Enter
.
6.
Input RAID size, press
Enter
. When asked
Are You Sure(Y/N)?
,