background image

Doc. No: 01999929 

Revision: C 

 

2 of 10 

Issue Date: 08/15/21 

INSTALLATION INSTRUCTIONS 

(Prior to assembly the parts must be reviewed enabling the assemblers to construct the units correctly in the least amount of 

time, the first time. Should questions arise during assembly contact Encon Safety Products at 800-283-6266. 

 

COMPONENT IDETIFICATION/PARTS LIST

ITEM NO.  NOMENCLATURE 

QUANTITY  PART NO. 

BOTTOM FRONT CONNECTOR TEE 

00011506 

TOP CONNECTOR TEE 

00011529 

BOTTOM REAR CONNECTOR ELBOW 

00011507 

FLOOR SUPPORT FLANGE 

00011613 

SCREW 

38 

00012805 

FENDER WASHER 

76 

00012788 

PANEL CUSHION CLAMP 

38 

00013115 

LOCK NUT 

38 

00011201 

VERTICAL STRUCTURE SUPPORT 

00010179 

10 

HORIZONTAL SIDE SUPPORT 

00000159 

11 

FRONT AND REAR HORIZONTAL SUPPORT 

00000158 

12 

SIDE PANEL 

01110214 

13 

REAR PANEL 

01110214 

14 

ROOF 

01110213 

15 

CONNECTOR HEX SCREW (NOT SHOWN INCLUDED W/PART) 

00012618 

16 

HEX WRENCH 

00011532 

17 

INSTRUCTION SHEET 

01999929 

NOTE:ALL PARTS SHOUD BE REVIEWED WITH ILLUSTRATIONS PRIOR TO ASSEMBLY.

 

PART I 

SHOWER SHELTER™ STRUCTURE ASSEMBLY INSTRUCTIONS 

1.  Inspect shipping container for damage. If exterior damage is observed, file a freight claim with the freight carrier as 

itemized on the invoice 

2.  Unpack shipping container contents and inventory against the parts list in the installation manual (see above). 
3.  Identify and locate the appropriate tools for assembly which include:  

a.  Pipe Wrench 
b.  Hex Wrench

(included)

 

c.  Flat Blade Screw Driver 
d.  Ratchet & 7/16” Socket 
e.  ½” Anchor Bolts as required 
f. 

6’ Step Ladder 

g.  Hole Saw 

4.  Set aside all nuts and bolts, washers, clamps, panels, and roof to be utilized in assembly instructions part’s

 II, III, IV, 

& V

SEE FIGURE’S 2 & 4.

 

5.  Lay out pipe and structural connections in an area of sufficient size to accommodate construction. The minimum 

recommended area for construction is 12’ x 12’. 

SEE FIGURE 3.

 

 

Summary of Contents for SHOWER SHELTER

Page 1: ...r around the shower equipment FIGURE 1 MODEL 01080024 The shower equipment may be located in the right or left rear corner or the center in the rear of the structure Thermaflow s with 32 overhead section w drench hose should be mounted in the rear corner only Assembly of the enclosure will require two people approximately a 12 x 12 assembly staging area and the tools as itemized in the manual Appr...

Page 2: ... 1 01110213 15 CONNECTOR HEX SCREW NOT SHOWN INCLUDED W PART 00012618 16 HEX WRENCH 1 00011532 17 INSTRUCTION SHEET 01999929 NOTE ALL PARTS SHOUD BE REVIEWED WITH ILLUSTRATIONS PRIOR TO ASSEMBLY PART I SHOWER SHELTER STRUCTURE ASSEMBLY INSTRUCTIONS 1 Inspect shipping container for damage If exterior damage is observed file a freight claim with the freight carrier as itemized on the invoice 2 Unpac...

Page 3: ... x3 12 Right Left Side Panel x2 13 Rear Panel x1 PART II FIGURE 4 SIDE STRUCTURE ASSEMBLY USE ILLUSTRATIONS AS NOTED 1 Slide ITEM 3 over threaded end of ITEM 9 and thread ITEM 4 creating a front vertical stanchion SEE FIGURE 5 Note Tighten ITEM 4 to ITEM 9 aligning bolt holes such that sufficient room for bolt placement is available see note on FIGURE 5 2 Place ITEM 1 over ITEM 9 and thread ITEM 4...

Page 4: ... vertical support pipe Lock in place by tightening hex set screw SEE FIGURE 7 Repeat for other side FIGURE 7 5 Insert ITEM 10 into ITEM 2 used in step 4 and place other end of ITEM 10 into the other ITEM 2 used in step 4 Tighten hex screws SEE FIGURE 8 6 Insert another ITEM 10 into ITEM 3 used in step 1 and place other end of ITEM 10 into ITEM 1 used in step 2 Tighten hex screws SEE FIGURE 8 7 Rep...

Page 5: ...erting 2 ITEM 11 s between the ITEM 2 s at the top and by inserting 1 ITEM 11 between the ITEM 3 s at the bottom Tighten hex screws SEE FIGURE 9 FIGURE 9 2 Raise structure and locate near the shower equipment If required remove the ITEM 11 located on the bottom to allow the structure to be placed around the shower equipment reconnect ITEM 11 afterwards ...

Page 6: ... insert into top center hole of ITEM 12 Place ITEM 7 over ITEM 10 with flat side towards panel SEE FIGURE 10 Lift ITEM 12 with UV tag side out onto ITEM 7 and attach as follows with ITEM 7 on ITEM 10 place ITEM 6 over ITEM 5 followed by ITEM 7 such that the flat side of the clamp lies against the fender washer Tighten ITEM 8 SEE FIGURE S 10 11 Note Panel can be supported by single top center clamp...

Page 7: ...teps 1 2 of panel assembly instructions assuring that the panel is centered prior to attachment of clamps SEE FIGURES 10 11 4 Repeat Steps 1 2 for the right side panel SEE FIGURES 10 11 5 Attach all remaining side and rear panel clamps flat side towards the panel SEE FIGURE 12 FIGURE 12 ...

Page 8: ... of ITEMS 10 11 SEE FIGURE 14 2 Place ITEM 14 over structure and fasten clamps to roof as in STEP 2 of PART IV Note Do not tighten until all clamps are in place with nuts on screws SEE FIGURE S 13 14 3 Tighten ITEM 8 on all roof clamps SEE FIGURE 14 4 Remove UV decals from the panels FIGURE 13 ITEM 4 Roof FIGURE 14 Roof Rear Side Panels Assembled ...

Page 9: ...es such that sufficient room for bolt placement is available 2 Mark bolt holes on pad and install anchor bolts supplied by others washer and lock nuts after placing structure over foundation SEE FIGURE 15 3 Inspect finished product for tight clamps joints and panels SEE FIGURE 16 FIGURE 15 FIGURE 16 Finished Shower Shelter Assembly ...

Page 10: ...ructions and properly installed if applicable in accordance with Encon s installation instructions With respect to the product Encon s only obligation and purchaser s exclusive remedy under this warranty is to repair or replace such product provided that 1 Encon is notified of the defect within one year of shipment and 2 the product is determined by Encon to be defective Encon requires proof of or...