OPERATION & MAINTENANCE 

1.  Plumbed units shall be activated weekly to flush lines and verify proper flow pattern and volume.  
2.  Test records should be maintained verifying compliance with testing procedures. 
3.  Some chemical vapors or liquids may damage or soften plastic materials. Precaution should be taken to determine 

compatibility prior to installation. 

TRAINING 

All employees who might be exposed to hazardous material shall be instructed in the location and proper use of emergency 
shower and eye/facewash units. Experiences have shown that initial first-aid treatment for irritates should be to wash the eyes 
and face for 15 minutes prior to medical treatment. It is important to hold the eyelids open and roll the eyes so water will flow 
on all surfaces and in the folds surrounding the eyes. 

PROPOSITION 65 

WARNING: This product can expose you to BPA, which is known to the State of California to cause birth defects or other 
reproductive harm. For more information go to www.P65Warnings.ca.gov. 

WARRANTY STATEMENT 

ENCON  HEREBY  DISCLAIMS  ALL  WARRANTIES  EXPRESSED  OR  IMPLIED  INCLUDING  BUT  NOT  LIMITED  TO 
WARRANTIES  OF  MERCHANTABILITY,  FITNESS  FOR  A  PARTICULAR  PURPOSE,  AND  NON-INFRINGEMENT  OF 
THIRD-PARTY RIGHTS, EXCEPT AS HEREINAFTER PROVIDED. 

Encon Safety Products warrants that for one year from the date of purchase of any Encon products, the product will be free of 
defects in materials and workmanship if properly used and cared for or cleaned under normal conditions in accordance with 
Encon’s use and care instructions and properly installed, if applicable, in accordance with Encon’s installation instructions. 
With  respect  to  the  product,  Encon’s  only  obligation  and  purchaser’s  exclusive  remedy  under  this  warranty  is  to  repair  or 
replace such product; provided that: 

1.  Encon is notified of the defect within one year of shipment, and 
2.  the product is determined by Encon to be defective. 

Encon requires proof of original ownership as proof of warranty coverage, and Encon must receive any claim under this Limited 
Warranty within one year of purchase of the product. 

NOTWITHSTANDING  ANYTHING  TO  THE  CONTRARY  CONTAINED  HEREIN,  ENCON  SHALL  NOT  BE  LIABLE  FOR 
LOSS,  DAMAGE,  OR  EXPENSE  ARISING  DIRECTLY  OR  INDIRECTLY  AS  A  CONSEQUENCE  OF  USE  OF  THE 
EQUIPMENT  WITH  OTHER  PRODUCTS  OR  FROM  ANY  OTHER  CAUSE,  INCLUDING  ANY  CONSEQUENTIAL, 
INCIDENTAL, SPECIAL OR EXEMPLARY DAMAGES, EXCEPT FOR ENCON’S OBLIGATION TO REPAIR OR REPLACE 
DEFECTIVE PRODUCTS AS EXPRESSLY PROVIDED IN THIS STATEMENT. 

Replacement parts purchased from Encon are warranted for one year following the shipment of such replacement part, or until 
the expiration of the warranty period for the product, whichever is less. No warranty is given in connection with products that 
are altered without Encon’s expressed written consent. The same warranty limitations and the obligations of Encon as set out 
herein above shall apply to replacement parts. 

Encon’s  total  liability  arising  out  of  this  warranty  (including,  but  not  limited  to,  warranty  claims)  regardless  of  forum  and 
regardless of whether such action or claim is based on tort, contract or otherwise will not exceed the total purchase price of 
the product. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

6825 W. Sam Houston Pkwy. N 

Houston, TX 77041 

1-800-AT-ENCON / 1-800-283-6266 

[email protected]

 

http://www.enconsafety.com 

Summary of Contents for SHOWER SHELTER

Page 1: ...r around the shower equipment FIGURE 1 MODEL 01080024 The shower equipment may be located in the right or left rear corner or the center in the rear of the structure Thermaflow s with 32 overhead section w drench hose should be mounted in the rear corner only Assembly of the enclosure will require two people approximately a 12 x 12 assembly staging area and the tools as itemized in the manual Appr...

Page 2: ... 1 01110213 15 CONNECTOR HEX SCREW NOT SHOWN INCLUDED W PART 00012618 16 HEX WRENCH 1 00011532 17 INSTRUCTION SHEET 01999929 NOTE ALL PARTS SHOUD BE REVIEWED WITH ILLUSTRATIONS PRIOR TO ASSEMBLY PART I SHOWER SHELTER STRUCTURE ASSEMBLY INSTRUCTIONS 1 Inspect shipping container for damage If exterior damage is observed file a freight claim with the freight carrier as itemized on the invoice 2 Unpac...

Page 3: ... x3 12 Right Left Side Panel x2 13 Rear Panel x1 PART II FIGURE 4 SIDE STRUCTURE ASSEMBLY USE ILLUSTRATIONS AS NOTED 1 Slide ITEM 3 over threaded end of ITEM 9 and thread ITEM 4 creating a front vertical stanchion SEE FIGURE 5 Note Tighten ITEM 4 to ITEM 9 aligning bolt holes such that sufficient room for bolt placement is available see note on FIGURE 5 2 Place ITEM 1 over ITEM 9 and thread ITEM 4...

Page 4: ... vertical support pipe Lock in place by tightening hex set screw SEE FIGURE 7 Repeat for other side FIGURE 7 5 Insert ITEM 10 into ITEM 2 used in step 4 and place other end of ITEM 10 into the other ITEM 2 used in step 4 Tighten hex screws SEE FIGURE 8 6 Insert another ITEM 10 into ITEM 3 used in step 1 and place other end of ITEM 10 into ITEM 1 used in step 2 Tighten hex screws SEE FIGURE 8 7 Rep...

Page 5: ...erting 2 ITEM 11 s between the ITEM 2 s at the top and by inserting 1 ITEM 11 between the ITEM 3 s at the bottom Tighten hex screws SEE FIGURE 9 FIGURE 9 2 Raise structure and locate near the shower equipment If required remove the ITEM 11 located on the bottom to allow the structure to be placed around the shower equipment reconnect ITEM 11 afterwards ...

Page 6: ... insert into top center hole of ITEM 12 Place ITEM 7 over ITEM 10 with flat side towards panel SEE FIGURE 10 Lift ITEM 12 with UV tag side out onto ITEM 7 and attach as follows with ITEM 7 on ITEM 10 place ITEM 6 over ITEM 5 followed by ITEM 7 such that the flat side of the clamp lies against the fender washer Tighten ITEM 8 SEE FIGURE S 10 11 Note Panel can be supported by single top center clamp...

Page 7: ...teps 1 2 of panel assembly instructions assuring that the panel is centered prior to attachment of clamps SEE FIGURES 10 11 4 Repeat Steps 1 2 for the right side panel SEE FIGURES 10 11 5 Attach all remaining side and rear panel clamps flat side towards the panel SEE FIGURE 12 FIGURE 12 ...

Page 8: ... of ITEMS 10 11 SEE FIGURE 14 2 Place ITEM 14 over structure and fasten clamps to roof as in STEP 2 of PART IV Note Do not tighten until all clamps are in place with nuts on screws SEE FIGURE S 13 14 3 Tighten ITEM 8 on all roof clamps SEE FIGURE 14 4 Remove UV decals from the panels FIGURE 13 ITEM 4 Roof FIGURE 14 Roof Rear Side Panels Assembled ...

Page 9: ...es such that sufficient room for bolt placement is available 2 Mark bolt holes on pad and install anchor bolts supplied by others washer and lock nuts after placing structure over foundation SEE FIGURE 15 3 Inspect finished product for tight clamps joints and panels SEE FIGURE 16 FIGURE 15 FIGURE 16 Finished Shower Shelter Assembly ...

Page 10: ...ructions and properly installed if applicable in accordance with Encon s installation instructions With respect to the product Encon s only obligation and purchaser s exclusive remedy under this warranty is to repair or replace such product provided that 1 Encon is notified of the defect within one year of shipment and 2 the product is determined by Encon to be defective Encon requires proof of or...

Reviews: