ENCARDIO RITE EAN-26 User Manual Download Page 9

Users’ Manual 

 

 

EAN-26 Digital inclinometer operation 

  

  

 

Page

 | 

6

 

4  READOUT UNIT 

The Digital Inclinometer system is using Mobile Phone as a Readout 
unit. Phone is running on Android operating system for providing 
powerful platform to manage applications efficiently. It has so many 
features like phone calls, SMS, MMS, GPRS/3G, Wi-Fi, Bluetooth, 
USB and high resolution Camera. User can use it as mobile phone 
for making calls. It has GPRS/3G which enables user to access 
internet from site to upload/download files and checking E-mails. 
Wireless Bluetooth can be used to send files to PC or any other 
Bluetooth device. High resolution camera can be helpful to take site 
conditions photographs and send them to the back office by sending 
MMS. It has higher capacity external memory card of 8GB which can 
store lots of data. Data backup can be taken on regular basis by 
connecting phone with PC through USB cable.    

4.1  Using the readout unit 

The inclinometer software running on phone can take borehole readings and store them into memory. 
Inclinometer software has ability to show borehole logs in tabular format and create plots of borehole data 
instantly after borehole reading is complete. Borehole data files are created automatically while saving 
borehole log. These files can be recreated from software database when needed. Borehole files can be 
uploaded to remote server through GPRS/3G/Wi-Fi. 

4.1.1  Establishing Bluetooth connection 

Inclinometer system is using Bluetooth connection for communicating Phone with Reel. Connect the probe 
with Reel. Turn ON the Reel by pressing push button provided on Reel’s disk near battery holder. Once 
push button is pressed Reel becomes ON. The indicator will glow in bright RED colour to ensure that reel 
is ON. Now power ON the Phone and go to settings and then Bluetooth settings. Turn ON the Bluetooth 
and click on “scan” button showing on phone’s screen. Phone will show the list of Bluetooth devices found. 
Find the Reel’s serial number on phone screen and click for pairing the phone with Reel. Once pairing 
button is pressed it will ask to enter passkey for authentication. Enter pairing code “6965785054” and then 
press OK. On successful authentication it will show that device is paired. Now Phone is paired with Reel. 
This activity is required for first time connection with Reel. 

4.1.2  Running inclinometer application on phone 

Running Inclinometer application is very simple. It is as simple as playing games 
in mobile phone. The graphic user interface makes it users friendly and thus easy 
to operate. Go to applications and then click on Digital Inclinometer application icon 
as shown in figure 5.2. Once DI application is clicked to run, it will show the name 
of the application and its version (see figure 5.3). This screen will splash for few 
seconds and then option menu appears. Figure 5.4 shows the option menu where 
we can change password for database deletion or regenerate deletion password. 
We can see help information by pressing help button or we can go to main menu 
to proceed further. 

Figure 5.1 

Figure 5.2 

Summary of Contents for EAN-26

Page 1: ...RITE ELECTRONICS PVT LTD A 7 Industrial Estate Talkatora Road Lucknow UP 226011 India P 91 522 2661039 42 Email geotech encardio com www encardio com International UAE Qatar Bahrain Bhutan Europe USA...

Page 2: ...Saving borehole log 14 4 2 Viewing data 15 4 3 Viewing data in table 15 4 3 1 Viewing data on graph 16 4 4 Borehole files storage 17 4 5 Borehole log database manager 17 4 5 1 Selecting multiple log f...

Page 3: ...26 7 3 Backing up the borehole logs 27 8 RESTORING INCLINOMETER DATA 29 8 1 Restoring the inclinometer database 29 8 2 Restoring borehole logs 29 9 TROUBLESHOOTING 31 9 1 Unable to connect Bluetooth 3...

Page 4: ...oing to be used for more than 30 days recharge the battery at least once every 30 days or so When battery voltage is showing 7 3V in system information screen at Readout unit it means approximately 10...

Page 5: ...are required for a biaxial inclinometer survey for each depth level in a bore hole In case of any error during logging the probe can be lowered back to the problem depth and logging continued without...

Page 6: ...vertical inclinometer probe can measure the tilt along a vertical plane passing through the probe axis A biaxial inclinometer probe can measure the tilt independently along two vertical planes that ar...

Page 7: ...reel is designed for use with variety of digital inclinometer probes from Encardio rite The probe calibration is independent of the Reel configuration The EAN 26MV digital Inclinometer probe uses two...

Page 8: ...four grooves in an inclinometer casing that has been chosen to be the reference groove After the first run is over the inclinometer probe is taken out of the casing and rotated 180 degrees and reinser...

Page 9: ...Inclinometer system is using Bluetooth connection for communicating Phone with Reel Connect the probe with Reel Turn ON the Reel by pressing push button provided on Reel s disk near battery holder On...

Page 10: ...graph using view data option Borehole files can be uploaded to a remote server using upload files button Borehole logged database can be managed using database manager option Site list shows the list...

Page 11: ...5 1 Inclinometer information Inclinometer screen shows the information about reel and the probe Figure 5 9 is showing an example of inclinometer screen of a reel It is showing the Reel s battery volt...

Page 12: ...te and Borehole menu can be opened on pressing create site button from main menu Figure 5 13 shows the site and borehole menu On pressing create button under site list it will open site creation menu...

Page 13: ...ault borehole selection menu Choose desired borehole to import parameters from Figure 5 16 is showing an example of default borehole selection menu Any borehole can be deleted by selecting a borehole...

Page 14: ...reading button from main menu Pressing on take reading button from main menu it will open reading screen as shown in figure 5 18 Lower the probe into borehole at depth showing on phone s screen Axis...

Page 15: ...en Once accept button is pressed it will save the reading and the depth and moved to next interval 9 5 meters in this case Pull the probe and fix it at 9 5 meters marking Wait until readings are stabl...

Page 16: ...N button can be used to reach the desired probe position Verify all readings at different intervals up to which readings are doubtful Application automatically exits from EDIT mode when highest logged...

Page 17: ...Set noise limit can be seen in terms measurement units Stable window can be adjusted depending on how noisy the readings are in the field It is recommended to keep stable window minimum 4 1 11 Saving...

Page 18: ...utton Figure 5 25 shows reset base file menu Choose a borehole file to set it base file and press OK View data menu figure 5 24 will show a list of borehole logs which are taken later to base file Sel...

Page 19: ...e can plot data on graph on pressing view graph button Use phone s back key to exit from this menu 4 3 1 Viewing data on graph On pressing view graph button from view data menu figure 5 24 application...

Page 20: ...hese CSV files are borehole log files generated while saving borehole log after taking readings refer section 5 1 11 Archive folder is used to keep uploaded files refer section 5 6 Figure 5 29 showing...

Page 21: ...p down menu To filter log list based on borehole select option by site and borehole and choose a site using drop down menu and then select borehole for which we want to see the logs To filter log list...

Page 22: ...So use this button when actually required 4 5 3 Creating files from borehole database Borehole files CSV DI1 can be created using create files button from database manager menu figure 5 30 Select bore...

Page 23: ...carefully Letters are case sensitive Press save button to save new password Remember this password for use in future 4 6 2 Forgot password If user forgets database deletion password then it can be re...

Page 24: ...ddress Provide port number of the FTP server Enter user name and password for authentication After providing all credentials press on save button to update URL settings Make sure that mobile phone hav...

Page 25: ...w press on upload button to upload selected files to FTP server Uploaded files will be moved to archive folder on successful completion of upload process Press cancel button to exit from this menu Ref...

Page 26: ...e B 5 1 Face error Face error is calculated using expression given below Face error should be almost constant with very small variations at every interval Ideally it should be zero Large and inconsist...

Page 27: ...spread sheet programs for formatted printing and graphical plotting It can also be imported in GTilt INCLINOMETER DATA SITE CODE Lucknow BOREHOLE CODE Charbag FACES LOGGED ABCD TIME DATE TAKEN 10 54 O...

Page 28: ...nated with a CR LF character ER DIV1 0 Borehole Data File SITECODE BOREHOLEID MAXDEPTH DATE TIME A 0 0 A 0 5 A 1 0 A 1 5 A 9 5 A 10 0 B 0 0 B 0 5 B 9 5 B 10 0 Lucknow Talktra 10 0 2011 08 11 10 46 07...

Page 29: ...ata cable phone will ask for connection type Choose connection type to Disk Drive and then click on Done A popup screen will appear on Desktop laptop s screen see figure 8 1 Select open folders to vie...

Page 30: ...ntents This folder contains two sub folders CSV files and web view files see figure 8 4 Open folder CSV files to view CSV files folder contents Figure 8 5 is showing an example of CSV files folder con...

Page 31: ...pen folder Web view files to view Web view files folder contents Figure 8 6 is showing an example of Web view files folder contents Select the files which backups are to be taken Copy these files to a...

Page 32: ...database Copy the preserved inclinometer database from safe location i e network servers etc Open folder DB_Inclino to view database folder contents Paste the database here and overwrite the existing...

Page 33: ...ration Page 30 Copy the preserved inclinometer Web view files from safe location i e network servers etc Open folder Web view files to view Web view files folder contents Paste the selected Web view f...

Page 34: ...Unable to connect to the probe Probe connector may be loose Turn OFF the Reel and reconnect the probe with reel cable and then turn ON the Reel Check the probe s connector for damage Reel s cable may...