Enatel DC System Manual
Page
20
of
26
Model: RWxxx
Version: 3.6
6.1
Default Settings
Table 5: Default Settings
Item
RW
312U
RW
324U
RW
348U
RW
512U
RW
517U
RW
624U
RW
748U
Boost Voltage
14.2V
28.8V
57V
14.2V
17V
28.8V
57V
Float Voltage
13.7V
27.4V
54V
13.7V
17.4V
27.4V
54V
Boost to Float
Current
2A
1A
0.5A
3A
3A
2A
1A
Over Voltage
Shutdown
16V
32V
60V
16V
18V
32V
60V
Temp Comp 25°C
13.7V
27.4V
54V
13.7V
17.4V
27.4V
54V
Temp Comp 5°C
14.16V 28.32V
55.9V
14.16V
17.61
28.32V 55.9V
LVD On Voltage
12V
24V
48V
12V
12V
24V
48V
LVD Off Voltage
10V
20V
40V
10V
10V
20V
40V
Current Limit
20A
10A
6A
35A
26A
20A
12A
6.2
Adjust Float Voltage
Connect a variable load (set to minimum load) to the battery connections of the rectifier.
Disconnect the Temperature Compensation Probe. Connect an accurate voltmeter across
the load. Turn the mains on to the rectifier. Wait approximately 10 seconds for the rectifier
to switch back to Float Charge mode. Check that the rectifier is in Float Charge mode (as
indicated on the LEDs).
Adjust the Float Voltage trimpot to set the required float voltage.
6.3
Adjust Boost Voltage
Connect a variable load (set to minimum load) to the battery connections of the rectifier.
Disconnect the Temperature Compensation Probe. Connect an accurate voltmeter across
the load. Turn the mains on to the rectifier and adjust the load until the rectifier goes into
Boost Charge mode (as indicated on the LEDs).
Note that there is a 10 second delay when switching from Boost Charge mode to Float
Charge mode, but no delay when switching from Float to Boost.
Adjust the Boost Voltage trimpot to set the required boost voltage.
6.4
Adjust Boost to Float Current Threshold
Connect a variable load (set to minimum load) to the battery connections of the rectifier.
Disconnect the Temperature Compensation Probe. Connect an accurate current meter in
series with the load. Turn the mains on to the rectifier, wait 10 seconds and then adjust