2.- The permitted heating of the cable according to VDE standard (minimum transversal section table required). 

I.e.: For 10 A, according to table for 15 A or less, the section is of 1 mm

2

Therefore, the section chosen is equal to 4 mm

2

, always chose the highest transversal section of the 

two verifications. 

4.3 PERIODIC MAINTENANCE  

MAINTENANCE WITH PETROL ENGINE

1.- 

Daily (8 hours).

 

Clean the motor and the beams, check the bolts & nuts, check and fill the motor’s reservoir with oil. 
2.- 

Weekly (50 hours).

 

Change the motor oil (first 20 hours), clean the sparking plugs and the air filter. 

3.- 

Monthly (200 hours).

 

Clean the oil filter, clean and adjust the sparks plugs. 

4.- 

Every 500 hours.

 

Clean and set the carburettor, clean the cylinder’s head, set the valves. 

5.- Always use original parts by every maintenance operation. 

6.- The safety fittings have to be checked after every maintenance. 
7.- 

Every  12 months

 or more frequently, the screed has to be sent to an authorized workshop for 

service according to the intensity of the usage. 

8.- Do not fill the fuel tank while smoking or near any other potential source of danger. 

Lock the petrol admission key when filling, use unleaded gas, clean the gas spelt. 

9.- Idle speed of the motor must not exceed 3.000 rpm (standard set). 

By  every  maintenance  operation,  the  idle  speed  of  the  engine  has  to  be  checked  and  adjusted  at 
3.000 rpm. See the engine’s manual to set the engine speed, starting and stopping. 

10.- 

Check the oil level in the exciter reservoir every 100 hours (10W 40 non foaming). 

MAINTENANCE WITH ELECTRIC MOTOR

1.- 

The operating of the electric parts must be done by a specialist. 

2.- 

During the maintenance, make sure that the device is disconnected from the power source. 

3.- 

Always use original parts by every maintenance operation. 

4.- 

The bearings of the motor do not need a periodic maintenance. 

5.- 

Inspect the plug, the socket as well as the cables every 100 Hours. 

6.- 

Periodically clean the housing of the motor to prevent an overheating. 

7.- 

The safety fittings have to be checked after every maintenance. 

8.- 

Every 12 months

 or more frequently the screed has to be sent to an authorized workshop for 

service according to the intensity of the usage. 

9.- 

Re-screw the nuts and bolts daily. 

Line (mm

2

)

Maximum (A)

Max fuse (A)

1

15

10

1,5

18

10/3-16/1-

2,5

26

20

4

34

25

6

44

35

10

61

50

16

82

63

25

108

80

Minimun section according VDE rules

NOMINAL INTENSITY X LINE LENGTH (A m)

SECTION LINE mm

2

2,5

1,5

10

4

6

25

16

6000

3000

1000

0

2000

4000

5000

115 V

230 V

380 V

8-800-555-58-36

                      

 

www.VibroMotors.ru 

                    

i

[email protected]

Summary of Contents for QGH

Page 1: ...iones Instruction manual Manuel d instructions Gebrauchsanweisungen MX 460 1406 REGLAS VIBRANTES FIJAS Y EXTENSIBLES FIXED AND EXTENSIBLE VIBRATING SCREEDS REGLES VIBRANTES FIXES ET EXTENSIBLES AUSDEH...

Page 2: ...TING STARTED 7 4 2 EXTENSION CABLES 7 4 3 PERIODIC MAINTENANCE 8 4 4 STORAGE 9 4 5 TRANSPORTATION 9 5 ELECTRIC SCHEME QP QPM 9 6 LOCATING MALFUNCTIONS 10 7 INSTRUCTIONS TO ORDER SPARE PARTS 10 7 1 INS...

Page 3: ...safety recommendations maintenance and usage listed in this manual Defective parts should be replaced immediately to avoid major problems The effective longevity of the equipment will increase if the...

Page 4: ...by an eccentric weight assembled with bearings inside a steel housing This housing also works as an oil tank for lubricating the bearings A belt transmits the movement from the engine assembled on fou...

Page 5: ...Clamp Beam Transport handle Switch support clamp Pulling handle Pulling handle Clamp Beam Transport handle Pulling handle Pulling handle Transport handle Engine Fuel tank Oil filler cap Stop button S...

Page 6: ...ERSONAL SAFETY STAY ALERT watch what you are doing and use common sense when operating a power tool DO NOT USE TOOL while tired or under the influence of drugs alcohol or medication DRESS properly DO...

Page 7: ...motor manufacturer s manual before working Do not work in closed rooms the exhaust fumes may be toxic Wait 2 minutes for the petrol refill until the motor gets colder 11 When working with an electric...

Page 8: ...ling the screed from the pulling handles 7 When the work is finished always remove the fresh concrete that has been settling on the beams and the motor before it gets dry 8 When a defect or a malfunct...

Page 9: ...eaded gas clean the gas spelt 9 Idle speed of the motor must not exceed 3 000 rpm standard set By every maintenance operation the idle speed of the engine has to be checked and adjusted at 3 000 rpm S...

Page 10: ...cause any damage 5 ELECTRIC SCHEME QP QPM CABLE SCHEME FOR ONE PHASE MOTOR CONNECTED AT 220 V QPM 1 PLUG 2P Earth 2 CABLE TO SWITCH SECTION 1 5 mm2 3 EARTH CABLE green yellow 1 5mm2 4 EARTH CONNECTION...

Page 11: ...mend including the MACHINE SERIAL NUMBER 2 The identification plate with serial and model number is located as shown in the point 2 of this manual 3 Let us to know the right shipping instructions incl...

Page 12: ...of concrete mass 2 When the mass is prepared the screed is laid over the concrete mass with the motor running at the top speed and you must pull the handles slightly in order not to spring over the su...

Reviews: