Draining the WT 2.1
Time required
20-30 minutes
Materials required
Clean 50L container (optional)
The module must be drained for transport and installation: to make it, switch off the device first using
the switch button on the frontal panel.
Step 1)
Attention: keep the unit powered off.
Step 2)
Prepare the container to catch the drained water (optional) and insert the end of the drainpipe
into it (Figure 4).
Step 3)
Fully insert the supplied male CPC quick connector 10mm Ø into the valve bulkhead labelled
"Drain." The solution will start pouring out immediately. It works by gravity, so be sure that
the pipe's end does not overcome the tank's water level (Figure 5 and Figure 6).
Step 4)
Once the water stops pouring, safely remove the drain connector.
Step 5)
To disconnect, push the button and pull the connector out of the bulkhead.