Version
Document Title
Release Date
02
Narrow Body EL2.1 (REV. A)
–
Owner's Manual
2021-03-22
EL 2.1 -
Owner’s
Manual - Rev.02
–
Mar 2021
32
Step 1)
Put on PPE. The minimum required equipment are safety goggles to protect
from splashes and nitrile gloves. Ensure your working area is clean to avoid
chemical contamination and potential exposure hazards.
Step 2)
Attention: the unit should be kept powered on, follow the instructions on the
app.
Step 3)
Make sure the "O2 VENT" has no tube or fitting attached to it.
Step 4)
Fully insert the supplied male CPC quick connector into the valve bulkhead
labelled "Electrolyte" as shown in the picture above.
Step 5)
Carefully raise the first-time filling solution above the device. Never lift the
electrolyte above your eye level.
Step 6)
The solution will start filling immediately, if this does not occur, ensure the
vent line is not obstructed.
Stop filling immediately if the App prompts you to stop!
If it is not stopped quick enough, the electrolyte can exceed the maximum
level. This will make the Electrolyser go into error - if this happens, the tank
must be drained, the Electrolyser put back in
maintenance mode
and the
process repeated.
Step 7)
Ensure all the solution has been filled into the device.
Step 8)
To disconnect, push the button and pull the connector out of the bulkhead.
You are done!
The device is ready to be used
. If you have any questions relating to the safety, installation and control
of the EL2.1, please refer to the
or contact Enapter support online via the cloud, or
by email or telephone.