46
5 Maintenance
Dismantling and rinsing the dual spout
The dual spout must be dismantled and rinsed
daily
if milk has been prepared to make sure it
functions perfectly and also in the interests of
hygiene. Your ENA will not prompt you to clean the
dual spout.
T
Remove the milk pipe and rinse thoroughly
under running water.
T
Press the releasing devices and pull the dual
spout down and off.
T
Push the milk system down and remove it.
T
Dismantle the milk system into its individual
parts.
T
Rinse all parts under running water. If there
are severely dried on milk residues, firstly
immerse the individual parts in JURA
Cappuccino Cleaner and then clean them
thoroughly.
T
Fit the air intake pipe.
T
Reassemble the milk system, noting the
numbering on the parts.
T
Insert the assembled individual parts into
the dual spout and press them together.
T
Fit the dual spout on the machine. It will
click into place audibly.
Inserting and activating the filter
Your ENA no longer has to be descaled if you are
using the CLARIS Blue filter cartridge. If you did not
activate the filter cartridge the first time you used
the machine, you can do this now as follows.
E
Perform the ‘inserting the filter’ operation
without any interruptions. This will ensure
that your ENA always produces its best.