Page 98
1.4.1 Low-Flow
04. 07. 2015
10:38
Activation
T ON
60.0°C
1.4.2 Quick-charging
04. 07. 2015
10:38
Activation
Sensors
T ON
T OFF
T targ.Coll.
TS3
48.0°C
52.0°C
70.0°C
1.4.3 disable recha...
04. 07. 2015
10:39
NLU at solar yield
Activ.time progr.
Start
End
08:00
22:00
PROFESSIONAL MODE
Here, the switch-ON temperature
can be defined for low-flow plants.
Continue with ›Quick-charging‹.
If the plant has been designed accordingly
and a system involving disable recharge
selected, the appropriate parameters
are set here.
The recharge suppression during solar charg-
ing can be activated here.
Here, the time control and/or the temperature
control are activated - possible for all systems
with heating boiler control.
Time and temperature control
can be used in combination.
Select the time slot via ›Start‹ and ›End‹.
Continue to scroll.
Tank quick charging changes over from
dT control to fixed temperature control.
›T ON‹ and ›T OFF‹ define the
change-over range and ›T targ. Coll.‹
the fixed temperature on the collector.
An upper tank sensor is
required for quick-charging.
Continue with ›Disable recharge‹.