Advanced Users
Advanced Users
-Input
=
camera name
•
Specifies the name of a camera. This camera must already have been configured in
Vigi
Control
-Close
•
If this command line option is specified with an ID, the window with that ID is closed.
-ShowState
={
Minimised|Restored|Maximised|Show|Hide
}
•
Sets the show state of the window.
•
To activate a window use Restored.
-AlwaysOnTop
={
On|Off
}
-AspectRatio
=[{
On|Off
|],[
width
],[
height
]
•
Switch the maintain aspect ratio feature on or off and specify the ratio of the width and height of the window.
•
All the values are optional but the commas must be used.
-Caption
=
•
Set the caption of the window. To include spaces, enclose the string in double quotes (“).
-ShowFrameRate
={
On|Off
}
•
Display or remove the current frame rate in the title bar,
-ShowMenuBar
={
On|Off
}
•
Use to specify if the menu bar is to be displayed.
-Window
=[
top
],[
left
],[
width
],[
height
]
•
Change the position and size of the window.
•
All the values are optional but the commas must be used.
-WindowStyle
={
BorderAndTitleBar|BorderOnly|NoBorderOrTitleBar
}
The following command line options allow changes to the appearance of the IP-Camera source. The numbers correspond to the
values displayed on the Input Settings sheet.
Networking Options
To control a window on a machine other than the one you are working on you will need some of the following options:
-Machine
={
machine name
|
IP address
}
•
Use this option to specify the machine to connect to.
-Port
=
port number
•
You need to specify the port if you are attempting to control a window on another machine and the server has been