![EMR iPM-1 Series User Manual Download Page 18](http://html1.mh-extra.com/html/emr/ipm-1-series/ipm-1-series_user-manual_2404521018.webp)
.
.
in the Default State (PTT=off).
Time Out Timer Auto Test:
Time Out Timer
This value sets how long the PTT Test Line will become “active” in seconds after the “PTT Test”
Submit Button has been clicked or an auto test is active. The default is 5 seconds, values are 0 to
60 seconds.
Auto Test:
If the accessory output for Push To Talk (PTT) is connected and programmed correctly the user may
use the Auto Test feature. With this enabled the PTT Line is switched to the “active” state every hour
allowing the RF Power to be sampled and VSWR calculated. If any of the Alarm Set points are
reached the unit will enter the alarm mode and a Time Date stamped entry of the alarm type is
entered to the Log.
Also, when this feature is enabled, check boxes are displayed in the email address that will
allow report every 24 hours to be sent.
Click the “Y” radio button to enable the Auto Test feature.
Click the “N” radio button to disable the Auto Test feature.
PTT Sense Setup
By clicking on the Power Sensor & Tests PTT Link on the left frame of the web page the Power Sensor & Tests PTT
page is displayed (see Fig. 22). PTT Sense can be set up on the PTT Sense Setup table (see Fig 24).
The User can Enter/Program the following;
Enable/Disable:
Click the “Y” radio button to enable the PTT Test Option.
Note: Only enable if the PTT Sense Line is installed.
Click the “N” radio button to disable the PTT Test Option.
16
Fig. 24