This value sets the sensitivity of a Low RF Alarm. “0” being the lowest and “255” the highest. Increase this
number in small increments if Low RF false alarms are experienced.
High VSWR Alarm Set Point:
This Value sets the High VSWR Alarm set point. Values should be entered to the second decimal.
For example “1.95”.
Email:
Select which of the Email Addresses entered on the IP page will be sent an email on an alarm by checking
any or all of the check boxes. Check box 1 corresponds with email address #1 up to email address #5. If
none are checked, no email notifications will be sent.
PTT Test Set up
By clicking on the Power Sensor & Tests PTT Link on the left frame of the web page the Power Sensor & Tests PTT
page is displayed (see fig. 22). PTT Test can be set up on the PTT Test Setup table (see Fig 23).
The User can Enter/Program the following;
Enable/Disable:
Click the “Y” radio button to enable the PTT Test Option.
Note: Only enable if the PTT Test Line is installed to the Transmitter.
Click the “N” radio button to disable the PTT Test Option.
Program Output:
Click the “Hi” radio button for a TTL level High (5 Vdc) to be applied to the accessory PTT Test line ( #11) in
the Default State (PTT=off).
Click the “Low” radio button for a TTL level Low (0 Vdc) to be applied to the accessory PTT Test line ( #11)