Enter a new password in the text box field (see Fig 12). It must be between 5 and 10 characters. Then click the
Submit button.
Note: The User Name is always “admin” in lower case, and the password is case sensitive.
Now click on the Power Sensor & Test PTT Setup to view the page.
You will be prompted for a user name and password (see Fig. 1). Enter admin for the user name and the new
password. Then click “OK”.
The Power Sensor & Test PTT Setup page can now be viewed.
It is assumed that this unit is to be installed to a VHF Repeater and that the installing technician has identified and
pre-wired the accessory cable for PTT, PTT Sense & COR Sense (see Fig. 17 and Fig. 37). Auto Test (key the
transmitter every hour to test) is also desired.
In this example, the PTT line requires a TTL Low for Transmitting and the COR goes high when active.
First, we will configure the
PTT Test Setup
table.
Since the PTT line requires a
low
to transmit, click on
Hi
in the Program Output Table “Default State”. Also, enable
the feature. Since auto test is desired, click “Y” under Auto test. Set the Time Out Timer to 5 Seconds (see Fig 13).