31792-4-1115
Page 17
COLINEAR TRANSITION VENT KIT
The Colinear Transition Kit (Part number PVCT) is available and
can be used to secure the flue and inlet pipes from the Mantis.
When venting vertically, the exhaust pipe termination must be a
minimum of 3 inches above the air inlet.
The flue can be terminated with a PTrap or two 90° elbows. The
Vertical Termination Cap (Part number PVVTC) can also be used
to terminate the flue pipe when using the Colinear Transition Kit.
AIR INTAKE
PTRAP OR 2 90° ELBOWS
SUPPLIED BY INSTALLER
TRANSITION PLATE
PVC CEMENT
PVC CEMENT
OUTDOOR SEALER REQUIRED
OPTIONAL
TERMINATION CAP
3” MIN.
REQUIRED HEIGHT IS 12” MINIMUM.
IT IS RECOMMENDED TO BE 12” ABOVE
THE MAXIMUM EXPECTED SNOW LEVEL.
AIR INTAKE
PTRAP OR 2 90° ELBOWS
SUPPLIED BY INSTALLER
TRANSITION PLATE
PVC CEMENT
PVC CEMENT
OUTDOOR SEALER REQUIRED
3” MIN.
EXHAUST
PTRAP OR 2 90° ELBOWS
SUPPLIED BY INSTALLER
REQUIRED HEIGHT IS 12” MINIMUM.
IT IS RECOMMENDED TO BE 12” ABOVE
THE MAXIMUM EXPECTED SNOW LEVEL.
Installation of the Colinear Transition Plate
1. Attach the plate to chimney chase, flat roof, or outside wall
with four screws. Use outdoor sealant to seal the transition
plate to the surface.
2. Cut inlet air pipe and flue exhaust pipe to correct lengths.
For vertical terminations through the roof or chimney, the air
intake and exhaust pipe termination must be a minimum of
twelve inches above the roof line. It is recommended that
the air intake and exhaust pipe termination be twelve inches
above the maximum expected snow level. See Figures 13
and 14. When venting vertically, the exhaust pipe termination
must be a minimum of three inches above the air intake. Also
refer to local codes. For horizontal termination through out
-
side walls, the minimum pipe length is nine inches for exhaust
pipe termination and six inches for the air intake.
3. Attach the flue and inlet air pipes to the transition plate. Use
the appropriate primer and cement to permanently bond the
joints and the pipes to the transition plate.
Figure 12
Figure 13
Available from Empire Comfort Systems, Inc.
Colinear Transition Plate
Note:
Must maintain a minimum 3” be
-
tween exhaust outlet and air intake.