30369-4-1013
Page 28
ALTERNATE ON/OFF SWITCH INSTALLATION
WIRING THE FIREpLACE
NOTICE
: Electrical wiring must be installed by a licensed
electrician.
CAUTION
DISCONNECT REMOTE CONTROLS IF YOU ARE ABSENT
FOR EXTENDED TIME PERIODS. THIS WILL PREVENT AC-
CIDENTAL FIREPLACE OPERATION.
Installation of Alternate Surround Panel ON/OFF Switch
An ON/OFF switch and wire assembly are provided. They are in-
cluded in the instruction packet.
Do not cut wire or insulation on metal edges.
NOTICE
: Refer to surround panel installation instructions for
additional information on attachment.
Contemporary Surrounds
1. Find the coiled low voltage wire assembly and ON/OFF switch
located in the instruction packet.
2a.
Millivolt Units:
Attach the flag terminal ends to the “TH/TP”
and “TH” terminals on the front terminal block of the gas valve.
See Figure 40.
2b. IP Unites: Disconnect the two black wires from the green
and white wire connectors. Connect alternate On/Off switch
wires to the green and white wires.
Note: This bypasses the On/Off switch located on the front of
the control module tray.
3. Run the low voltage alternate switch wires over to the right
or left surround panel. Then secure the wires with wire clips
provided.
See Figure 39.
Right Side Installation
Left Side Installation
ON/OFF
SWITCH
ASSEMBLY
ON/OFF
SWITCH
ASSEMBLY
WIRING FROM
MILLIVOLT GAS
VALVE
Figure 39
Insert ON/OFF switch into side panel then attach wire as
-
sembly from valve terminals on millivolt units, or from the
green and white wire connectors on IP units.
4. Remove the switch knockout on the side surround panel, then
install the ON/OFF switch. See Figure 39.
5. Connect the low voltage wires from the gas valve to the
ON/OFF switch.
6. Attach the surround panel assembly to the fireplace. Hang
the surround panel assembly on the face of the fireplace
and center left to right.
DF(25,33)M4 Surrounds:
Swing the surround panel assem-
bly inward until the bottom magnets contact the fireplace body
side flanges.
For DS(25,33)66BL Surrounds:
Swing the surround as-
sembly inward, then lift each leg slightly to engage the re-
tainer hook into the side flange notches of the fireplace.
All surrounds: This secures the surround panel assembly to
the fireplace without screws.
Figure 40