30369-4-1013
Page 18
SEE CHART FOR
PERMISSIBLE
“H” AND “V”
DIMENSIONS
A
CENTER OF ELBOW
STRAIGHT OUT
(MINIMUM)
10”
(254mm)
C
B
V
C
B
H
11”
(279mm)
BOTT
OM
OF
FIREPLAC
E
2 FOOT MIN.
VERTICAL PIPE
VENT CAP
9” (229mm) minimum
TO SIDE WALL
Figure 22
Figure 23
FIREpLACE
SERIES
HARD ELBOW DIMENSIONS
"A"
"B"
"C"
"D"
DVL25FP
49 1/4”
(1,250 mm)
4 1/2”
(114 mm)
6 1/2”
(165 mm)
9 1/8”
(232 mm)
DVL33FP
52 1/4”
(1,327 mm)
4 1/2”
(114 mm)
6 1/2”
(165mm)
9 1/8”
(232 mm)
FIREpLACE
SERIES
FLEX pIpE 90 DEGREE BEND
"A"
"B"
"C"
"D"
DVL25FP
49 1/4”
(1,250 mm)
4 1/2”
(114 mm)
6 1/2”
(165 mm)
9 1/8”
(232 mm)
DVL33FP
52 1/4”
(1,327 mm)
4 1/2”
(114 mm)
6 1/2”
(165 mm)
9 1/8”
(232 mm)
MINIMUM HOLE LOCATION DIMENSIONS FOR THROUGH
THE WALL HORIzONTAL INSTALLATIONS WITH 90 DEGREE
ELBOW OFF TOp OF FIREpLACE
SEE FIGURE 17 VENTING CHART FOR PERMISSIBLE "H" AND
"V" DIMENSIONS.
VENTING FIREPLACE - TOP (continued)
Positioning the Fireplace
Determine the exact position of the appliance so the direct vent
termination will be centered (if possible) between two (2) studs. This
will avoid any extra framing. All vent kit pipes should be assembled
on the unit after the unit is secured into the final position.
Cutting the Hole
After the fireplace has been positioned in its permanent location,
the hole through the exterior wall of the house can be cut. This
hole must be 11" (279mm) high x 10" (254mm) wide with its center
line determined by the amount of vertical rise and horizontal run of
the termination. (See Figure 21) When locating the hole it must be
noted that the bottom of the cap must be 12" (305mm) above the
ground level, and top of the cap must be no less than 18" (457mm)
below a combustible projection, and no closer than 9" (229mm) to
any wall running parallel to vent termination. See Figures 27 and 28.
Note: A minimum 2’ vertical rise is required off the top of the
fireplace with all acceptable vent systems.
Figure 21