37607-1-0817
Page 19
Figure 26
NOTICE:
Island and room divider installation is possible as long as the horizontal portion of the vent system does not exceed 20 feet with
a minimum vertical run of 8 feet. See details in Venting Section.
When you install your Direct Vent Fireplace in Room divider or Flat on wall corner positions, a minimum of 6 inches clearance must be
maintained from the perpendicular wall and the front edge of the appliance.
LOCATING FIREPLACE
JUNCTION BOX WIRING INSTALLATION INSTRUCTIONS
BLACK (HOT)
BRASS SCREWS
JUNCTION BOX
WHITE (NEUTRAL)
BARE (GROUND)
SILVER SCREWS
GREEN SCREWS
120 VOLT POWER SUPPLY
JUNCTION BOX WIRING
Figure 27
Junction Box
For electric accessories such as a light kit or blower, make all
wiring connections inside the junction box located on lower right
side of fireplace.
Attach black to black and white to white. Attach the ground wire to
the ground on the junction box.
(Figure 27)
NOTICE:
A one-inch diameter hole should be use to pass wiring
through studs.
CAUTION
All wiring shall be done by a qualified electrician and shall be in compliance with all local, city and state building codes. Before making
the electrical connection, make sure that the main power supply is disconnected. The appliance, when installed, must be electrically
grounded in accordance with local codes, or in the absence of local codes, with the National Electrical Code ANSI/NFPA 70 (Latest Edition).